CO DETECTORS

0 out of 5

FG731 CO ALARMS ARE UL APPROVED STAND-ALONE CO DETECTORS POWERED FROM 5-YEAR LONG-LIFE INTERNAL BATTERIES.  


Features
  • Advanced algorithms provide advanced detection discrimination
  • Attractive housing design
  • Japan-made highly reliable stable CO sensor, with automatic adjustment
  • High immunity against unwanted alarms
  • Loud 85 dB internal alarm sounder
  • Dual function action button to temporarily silence unwanted alarms (Hush), and to verify alarm operation (Test)
  • Separate indicators for Power, Alarm and Service
  • Service sounder
  • Low power consumption
  • Low battery audible indication
  • Easy installation. No programming required
  • 5-year "end-of-life" timer alerts owner to replace the unit

View

CONSEALED SPRINKLER

0 out of 5

The FA019/FA020 Standard/Quick Response Concealed Pendent Sprinklers are automatic sprinklers of the frangible bulb type. They are “standard/quick response – standard orifice spray sprinkler” intended for use in fire sprinkler systems designed in accordance with the standard installation rules recognised by the applicable Listing or Approval agency (e.g., UL Listing is based on NFPA 13 requirements). The Concealed Pendent Sprinklers all produce a hemispherical water distribution pattern below the deflector.

  • FA019, FA020
  • FA007C,FA008C (optional model)

View

CONVENTIONAL PANEL

0 out of 5

FGZ series conventional "Fire alarm control panel supports 1/2/4 zones and 3 groups of sounders. Each zone can connect up to 50 smoke detectors, heat detectors, manual call points, etc. All zones and sounders of the "Fire alarm system can be disabled. All input and output devices are monitored by the control panel, and the control panel will automatically disconnect when the zones or sounders are short. The control panel can provide 24VDC / 300mA power for products that require an additional24V power supply. The detailed status indicators clearly show the working status of the control panel and provide the "First Fire alarm and subsequent "Fire alarm functions. After the control panel sends a "Fire alarm signal, it can provide up to 120 seconds delay time to con rm whether there is a real re alarm. In addition, the control panel also provides the mains-lost silence function. After configure the mains-lost silence mode, the control panel will no longer send a fault signal to remind the user when the main power is lost.  


Technical Data
  • Main power: AC220V± 15%,S0Hz/ AC110V± 15%,60Hz
  • Zone voltage: 24v±2V
  • Number of zones: 1,2,4
  • Zone and sounder end of line resistors: 3.9KO, 1 W
  • Zone monitoring current: <4.SmA
  • Zone alarm current: > 20mA
  • Zone short current: > 1 10 mA
  • Battery: DC 24V ( 2 x 12V 3.3Ah)
  • Sounder alarm output: 3 x 300mA (max}/24VDC
  • Auxiliary Supply: 300mA/24V
  • One set of fault relay contacts: Rated at 0.SA SELV
  • Humidity: :o;95%RH
  • Dimensions: 290 x 87.5 x 211.5mm
  • weight: 2100g (without battery)

View

CORRESPONDING CONTROLLER

0 out of 5

It is responsible for information transfer within a certain area, thus increasing the number of subordinate devices and facilitating data.


Specification
  • Model: FG-REP01  
  • Voltage AC120V/0.035A or AC277/0.016A 50/60Hz  
  • AC Power 3W Battery Ni-MH - AA 600MAH/4.8V  
  • Emergency 3Hours Duration  
  • Communication 485 BUS BUS

View
,

DEISEL ENGINE

0 out of 5

CLARKE fire engines has the world’s largest range of UL/FM approved diesel fire pump drivers. Clarke Fire Engine covers UL /FM pump requirements from 31 kw to 764 kw with operating speeds from 1470 RPM to 3000 RPM All Clarke engines are supplied with a standard 24-month manufacturer’s warranty Clarke Fire engine has innovative and patented Pressure Limited Driver diesel engine which protects the sprinkler system from over pressurization by varying engine RPM Clarke fire engine has dual starting technology as well as the technology for dual ECM electronic injection engines. Both increased diesel engine reliability and performance. Its driveshaft style couplings solved field alignment problems, and significantly reduced the time needed for engine/fire pump installation and maintenance. Clarke has implemented an exciting, ongoing and continuous product improvement program which will provide even more high-quality Clarke engine models to meet and exceed the demands. A deduction of 3% of the power is made for each 1000 feet rise in altitude above 300 feet and 1%for each 10 Degree above 77 Degree ambient temperature. Minimum instrumentation and control including adjustable speed governor, over speed shutdown device set approximate 20 above rated engine speed, tachometer with hour meter, oil pressure gauge and temperature gauge. Most diesel engines models work seamlessly with FIREGUARD fire pumps. Working together, they deliver the most efficient and reliable fire pump solutions. Our integrated diesel pump units make us stand out in the market. Optional: NM Fire Engine, Kirloskar

View
,

DELUGE VALVE MODEL C1,N1 & D1

0 out of 5

Deluge Valve is an automated system control valve, used for fast application of water in a spray system. Deluge valve protects areas such as power transformer installation, storage tank, convey or protection and other industrial application etc. With the addition of foaming agent deluge valve can be used to protect aircraft hanger and inflammable liquid fire. Deluge valve is a quick release, hydraulically operated diaphragm valve. It has three chambers, isolated from each other by the diaphragm operated clapper and seat seal. Model: C1 (Cast Steel) Model: D1 (Ductile Iron) Model: N1 (Nickel Al Bronze)(applicable for sea water)

View

DISTRIBUTED CONTROLLER

0 out of 5

It is responsible for information transfer within a certain area, thus increasing the number of subordinate devices and facilitating data.  


Specification
  • Model: FG-INT01  
  • Voltage AC120V/0.035A or AC277/0.016A 50/60Hz  
  • AC Power 3W Battery Ni-MH - AA 600MAH/4.8V  
  • Emergency 3Hours Duration  
  • Communication CAN BUS BUS AND 485 BUS

View
,

DRY BARREL HYDRANT 250 PSI

0 out of 5

Fireguard has designed hydrants to assure reliable and high-performance product according to ANSI/AWWA C502, UL246 and FM1510 standard requirements. Dry barrel hydrants have been used in fire protection for over 100 years. Hydrants are considered as critical piece of emergency equipment and should be fully reliable equipment to function when required. Fireguard hydrants are easy to maintain and are supplied with repair kits. Hydrant body is of ductile iron with stainless steel stem. The wedge is of ductile iron fully encapsulated with EPDM rubber. Designed as per AWWA C502 Meets or exceeds all the latest provision of AWWA and UL 246 FM 1510 standards. Break away design to prevent accidents to the hydrants, where only the upper part of the flange would be broke upon impact. High working pressure of 250psi with 500psi testing pressure Simple rugged construction and easy to maintain 2 x 2.5” NST hose nozzles + 1 x 4” NST pumper nozzle Fully and easily lubricated operating threads for corrosion protection Barrel length extension kit in different lengths is available on request. Besides repair kits for our hydrants have various accessories such as extension spindles, Street covers, Different stem caps which completes our valves and hydrants. Model:

  • Model FGH 701 & FGH 702
  • Model FGH 701 - 4.5/2.5
  • Model FGH 701 - 4/2.5

View
,

DRY BARREL PILLAR HYDRANT

0 out of 5

FIREGUARD Dry Barrel Hydrant has been LPCB Approved and is designed as per international standards. Our Hydrant confirms to BS EN 14384: 2005, BS 1074-1, BS 1074-2 & BS 1074-6 Standards. The hydrant has a Break away design to prevent accidents to the hydrant, where only the upper part of the flange would be broken upon impact, when broken it is still able to maintain the seal and there is no leakage of water. Automatic drain system drains the water in the upper part when the main valve is closed, thus avoiding damage caused by freezing. Model:

  • FGDH100 Dry Barrel Hydrant 4"
  • FGDH150 Dry Barrel Hydrant 6"

View
,

WET BARREL HYDRANT

0 out of 5

Fireguard produces various types of wet barrel hydrant designed to be a trouble free, easy to maintain hydrant. The hydrant is rated for a working pressure of 250 psi, is UL listed, and meets or exceeds the requirements of the AWWA C503 standard for wet barrel fire hydrants This type of hydrant is equipped with outlet valves which has pressurized water at every outlet constantly. Wet Barrel Hydrants are used in conditions where there no possibility of water freezing due to weather conditions.

View

Dual Module IQ611DM

0 out of 5

The IQ611DM dual input module supports two Class B input circuits, each of which can monitor a dry contact device. The input line is monitored for open line faults and ground faults, and the contact must be wired with an end-of-line resistor. It is an intelligent addressable module and takes two addresses on the Signaling Line Circuit (SLC) or Data Communication Link (DCL) of the fire alarm control panel. Two LED indicators are employed to indicate each input circuit’s condition. The IQ611DM is a UL listed device according to UL864 for Fire Alarm Systems for indoor use.

View