Addressable module with integrated isolator in micro format FG901MMI_AP/ FG901MMO_AP /FG901MMIOS_AP

0 out of 5

Using the FG901MM range devices it is possible to interface various types of devices to the LOOP or to activate any type of output such as sirens, entrance panels, electromagnets, etc. FG901MM range is used in combination with the control units equipped with protocol to monitor and control many devices. Each FG901MM can be addressed manually, by programmer or by fire detection control unit with protocol or with auto addressing by fire detection control unit with protocol. The input channels monitor the rest, alarm and fault condition through the balancing resistors provided.

View

ATMOSPHERIC FOAM CONCENTRATE STORAGE TANK

0 out of 5

The atmospheric foam concentrate storage tank is manufactured in stainless steel material. The tank is provided with an expansion dome with a volume not less than 2% of the total capacity of the tank. All the tanks must be kept filled upto the level of half way of expansion dome. A sediment sump is provided at the bottom of the concentrate tank. The tank is provided with an inlet, an outlet, a drain connection and a fill connection. The horizontal tanks are supported by two saddles/legs welded to the tank and drilled for anchoring. Tank is provided with lifting lugs, designed to lift empty tanks. The tank has flat ends but can be provided with dished ends if needed. Atmospheric foam concentrate storage tank is used with Inline Foam Inductor and Inline Balance Pressure Foam Proportioning system. Refer to data-sheets/ product catalogues of these devices for equipment operational and installation guidelines.

View
,

BUTTERFLY VALVE GROOVED END & WAFER TYPE 300PSI

0 out of 5

The Grooved End & Wafer type Butterfly valves are indicating type designed for use in fire protection systems where a visual indication is required as to whether the valve is open or closed. They are used, for example, as system, sectional, and pump water control valves. They have cut groove inlet and outlet connections that are suitable for use with grooved end pipe couplings that are listed and approved for fire protection systems. For applications requiring supervision of the open position of the valve, the Gear Operators for the Model BO-G Butterfly Valves are provided with two sets of factory-installed internal switches each having SPDT contacts. The supervisory switches transfer their electrical contacts when there is movement from the valves normal open position during the first two revolutions of the hand wheel.

View

FIRE HOSE - DURA-LINE TYPE 3

0 out of 5

Fireguard produces various types firefighting hoses with high quality for most demanding situations. All hoses are manufactured according to national fire protection association (NFPA)1961 latest edition. The Fireguard Model Dura-line FGH303N synthetic fire hose is widely used by firefighters worldwide. This hose features: is tough durable and abrasion resistant, supplied with different couplings. The Nitrile rubber cover makes rot proof and easy to clean. Construction-polyester reinforcement with Nitrile rubber cover and inner liner Nitrile rubber.

View

Gas Weight Monitoring System Analog type with Normal Indication (Standalone)

0 out of 5

Online Monitor is used in Gas based fire extinguisher system like Co2 to provide alert indication to check refill as per bureau of Indian standards requirement. Normal condition will be indicated by green LED (Flashing). Alert will be indicated by yellow LED. IH007-ST online monitor analog type is stand alone model this is specially designed to use monitor one cylinder only. Input will be 24V DC and Output will be potential free ‘NO’ contact.

View

Gas weight Monitoring System Mechanical Indicator Type

0 out of 5

Online Monitor is used in gas based fire extinguishing system like Co2 gas to provide alert indication to check refill is required to meet NPFA/BSI requirement. Movement of indicator in downward refill status. Please note that this device is not a weighing unit. This only provide alert indication to check the cylinder and do refill as per requirement.

View

Gas Weight Monitoring System Mechanical Indicator Type With Explosion Proof Limit Switch

0 out of 5

Online Monitor is used in Co2 Gas based fire extinguisher system to provide refill alert indication in case of loss of agent as per design standards. Movement of indicator in downward position indicates alerts status. Ex. Proof limit switch can be additionally used to provide further signal at control panel.

View

Input/Output Addressable module with short circuit isolator FG901MIO3_AP / FG901MIO_AP / FG901MI3_AP / FG901MIO2_AP

0 out of 5

The new series of analogue multi modules of the FG901MI line implements supervision and monitoring functions for the activation and supervision of auxiliary devices. Each FG901MI can be addressed manually, by programmer or by fire detection control unit with protocol or with auto addressing by fire detection control unit with protocol. The input channels monitor the rest, alarm and fault condition through the balancing resistors provided. The output channels can be either monitored or form C type. In the case of monitored output, the end of line (cut, short cables) and the presence of the power supply on the load, supplied with end-of-line resistance and diode are checked. In the case of form C output, the module offers potential free relay contacts.

View

Multi Candela Horn and Strobe IQ671HS

0 out of 5

The IQ671HS Horn Strobes is multi-candela visual and audible signal appliances with light sources generated from white LED, listed according to UL 1971, UL 1638, UL 464, ULC-S525 and ULC-S526 for indoor use. The LED light source offers superior performance, including low power consumption and long operating life. Six levels of light output are selectable. Figure 1 shows relative light outputs in horizontal and vertical dispersion from strobes mounted on walls/ceilings. The strobe appliances produce a flash rate of one flash per second over the Regulated Voltage Range. The temporal tone generated by the horn portion is designed as per ANSI and NFPA72 for standard emergency evacuation signaling requirement. The appliance has the feature that can synchronize multiple horn and/or strobes in a complete fire alarm system.

View