RETARD CHAMBER

0 out of 5

UL Listed and FM Approved retard chamber designed for use with alarm valve trim in systems where variable water pressure is anticipated. Acting as a holding tank, the RC9 prevents false alarms triggered by pressure surges while ensuring the sprinkler alarm activates reliably during a sustained water flow event.

Connected between the alarm valve port and the sprinkler alarm via a restriction nozzle assembly, the chamber fills only when flow exceeds the drain nozzle capacity — allowing the alarm and pressure switch to activate with confidence. Constructed from stainless steel for long-term durability and corrosion resistance.

Key Specs:

  • Model: RC9
  • Material: Stainless Steel
  • Connection: 3/4" BSPT (F)
  • Rated Pressure: 17 bar (250 PSI)
  • Weight: 2.6 Kg
  • Approvals: UL Listed & FM Approved

Compatible with Model H Alarm Valve. Must be installed in accordance with NFPA standards. The restriction nozzle orifice and screen should be inspected and cleaned regularly to prevent blockage.

View
,

RIM SEAL FOAM POURER

0 out of 5

UL Listed air-aspirating rim seal foam pourer designed for the protection of open top floating roof storage tanks in accordance with NFPA 11. Classified as a Type II discharge outlet, the RPA delivers fully aspirated low expansion foam directly and gently into the annular seal area between the floating roof rim and the tank shell.

Comprising an integrated foam maker, windshield, and integral deflector, the RPA unit is a complete, self-contained assembly. Each unit is supplied with a flow-specific orifice plate, with a field-replaceable orifice to accommodate future design changes. Air is drawn into the foam solution via a venturi inlet and filtered through a stainless steel screen to prevent ingress from birds and insects.

Key Specs:

  • Models: RPA (Carbon Steel) | RPA-S (Stainless Steel)
  • Inlet Size: 65NB
  • Working Pressure: 2.8 to 7 Kg/sq.cm (40 to 100 PSI)
  • Flow Range: 50 to 550 LPM
  • Flange Connection: ANSI B16.5 Class 150#
  • Finish: Red RAL 3000
  • Approval: UL Listed

Compatible with Inline Foam Inductors, Balance Pressure Foam Proportioning Systems, Bladder Tank Systems, and Foam Tenders. System design must comply with NFPA 11. A pressure gauge provision at the RPA inlet is recommended during commissioning.

 

View

Sounder Base

0 out of 5

IQ651BH sounder base supports both external and SLC loop powering working modes that can be set with programmer IQ612. IQ651BH sounder base is compatible with IQ651S smoke detector and IQ651H heat detector. When set as horn strobe and assigned unique address in loop, the panel will automatically synchronize the tone of the sounder. An integrated dip switch can select between temporal 3 and continuous tones. When saving SLC address resourcing is desired, and tone synchronization is not required, the address of the sounder base can be set as the same address as the detector it is installed with. In a suite room, it’s often required to trigger multiple sounder bases when a detector alarms. Program the logic in the panel to set up the operation logic. The number of sounders triggered by one detector is not limited in the loop.


Features
  • 24VDC external powering or SLC loop powering selectable with programmer
  • SLC loop power supply
  • Use the same address as the detector installed
  • Logic operation as programmed*
  • Work as separate sounder when used with accessory cover IQ651BH-F
  • Support Class A and Class B wiring
  • Min. 80dB sound output
  • UL 94-V0 flame-retardant plastic
  • Non-polarity external 24VDC power input
  • Remote LED output
  • Automatic Sync. under horn strobe mode (set at programmer & set unique address in loop)
  • Temporal 3 or continuous tones selectable with dip switch

View
,

TEST & DRAIN VALVES

0 out of 5

Test & Drain with an integral sight glass assembly, provides a simplified means for testing of waterflow alarm devices and draining of feed mains. Test and drain valve is a 300 PSI rated single handle ball valve that was specifically designed to provide both the test function and the express drain function required for a wet fire sprinkler system. It include tamper resistant test orifice and sight glass for maximum visibility when operated. Model: FGT1000  

View
,

UNDERGROUND HYDRANT

0 out of 5

A robust underground fire hydrant manufactured with a cast iron body, fully compliant with BS 750, BS EN1074-2:2000, and EN 14339:2005 standards. Featuring a 2½" male outlet with removable plastic cap protection and blue epoxy resin coating for durability. Designed for cold water use with universal inlet flange compatibility. Operated using fire hydrant standpipes with key and bar for valve control.

Technical Specifications

Feature

Specification

Body Material

Cast Iron

Outlet Connection

2½" Male (secured with M12 bolts)

Inlet Flange

Universally drilled to EN1092-2 PN10/16 and BS10 Table D/E

Coating

Blue epoxy resin (internal and external)

Design Standards

BS 750, BS EN1074-2:2000, EN 14339:2005

Water Type

Cold water use

Outlet Protection

Removable plastic cap

Available Sizes

Size

H (mm)

W (mm)

Key

Outlet

DN80 Flange

270

286

35

BSPT

DN80 Flange

270

286

35

DN80

DN100 Flange

270

286

35

BSPT

DN100 Flange

270

286

35

DN80

Applications

  • Water Companies
  • Industrial Sectors
  • Construction Projects
  • Groundworks

Operation

Fire hydrant standpipes screw onto the outlet, and a fire hydrant key and bar is used to open the valve for water flow.

View
,

WATER CURTAIN NOZZLE

0 out of 5

Water Curtain Nozzle distributes water in a flat curtain extending all the way to the ground, producing a continuous water barrier to segregate an area under fire. When mounted in a horizontal position with flow directed towards the ground, the nozzle creates this flat-water curtain effect for fire segregation. Available in Brass and Stainless Steel construction with a range of flow rates, the Water Curtain Nozzle is suited to deluge fire protection systems requiring reliable area separation.

For best performance, nozzles should be spaced a maximum of 2.5 meters apart.

Key Specs:

  • Models: WC-15 / WC-20 (Brass — 1S319 / ASTM B16) | WC-15S / WC-20S (Stainless Steel)
  • Maximum Working Pressure: 12.3 Kg/sq.cm (175 PSI)
  • Effective Working Pressure: 1.4 to 3.5 Kg/sq.cm (20 to 50 PSI)
  • End Connection: WC-15/WC-15S — ½" BSPT (NPT optional) | WC-20/WC-20S — ½" BSPT (NPT optional)
  • K-Factor: WC-15/WC-15S — K23, K30, K37, K45, K53, K72 | WC-20/WC-20S — K98, K120, K140
  • Approximate Weight: WC-15 — 0.180 Kg | WC-20 — 0.250 Kg
  • Finish: Nickel chrome or Brass (WC-15 & WC-20) | Natural (WC-15S & WC-20S)

Dimensions (Model / A / B, in mm):

Model A B
WC-15 & WC-15S ½ BSPT 42
WC-25 & WC-20S ¾ BSPT 46

When ordering, please specify Model, K-factor, and Finish.

View

WATER MOTOR GONG

0 out of 5

FM Approved hydraulically driven mechanical alarm bell designed to provide an immediate audible alert when a fire sprinkler system activates. Requiring no electrical power or external lubrication, the Model GA is a reliable, self-contained alarm solution for wet pipe and deluge sprinkler systems.

When water flows through the alarm or deluge valve, it enters the motor housing via a nozzle, driving the impeller and striker arm to strike the aluminium gong — producing a loud, continuous alarm signal. Constructed from corrosion-resistant aluminium alloy, it is built to withstand demanding environments.

Key Specs:

  • Max Working Pressure: 12.3 Kg/sq.cm (175 PSI)
  • Min. Activation Pressure: 0.35 Kg/sq.cm (5 PSI)
  • Connection: Inlet 3/4" BSPT (3/4" NPT) | Drain 1" BSPT (1" NPT)
  • Gong Diameter: 205mm (8") | Gong Depth: 50mm (2")
  • Finish: Epoxy red powder-coated
  • Weight: 3.0 Kg
  • Mounting: Type A (surface) & Type B (through-wall)

Key Features: No electrical supply required, lightweight non-metallic impeller and drive shaft, corrosion-resistant aluminium alloy construction, and suitable for both indoor and outdoor installation.

Must be installed in accordance with NFPA 13 requirements. A 3/4" strainer in the alarm line is required to protect the nozzle from clogging.

View

Vane-Type Waterflow Detector – VTWS (Saddle) / VTWT (Threaded)

0 out of 5

Fireguard vane-type waterflow detectors are compatible with schedule 10 through 40 steel pipe, sizes 2 through 8 inch, and can be mounted in vertical or horizontal position. Available in saddle type (VTWS) or threaded type (VTWT) connection, both consist of a rugged, NEMA 3-rated enclosure suited to indoor and outdoor use across a wide temperature range. UL Listed models feature tamper-resistant cover screws, and inside, two sets of SPDT (Form C) synchronized switches are enclosed in a durable terminal block for reliable performance. A mechanical retard feature minimizes false alarms caused by pressure surges or trapped air in the sprinkler system, with a sealed design immune to dust and contaminants. Both the retard mechanism and dual SPDT switches are field-replaceable.

Key Features:

  • Two-inch mounting hole provided
  • UL-Listed models NEMA 3 rated, FM Approved
  • Sealed retard mechanism, immune to dust and contaminants
  • Visual switch activation
  • Field-replaceable retard mechanism and SPDT switches
  • Accommodates up to 12 AWG wire
  • Designed for indoor and outdoor use
  • 100% synchronization activates both alarm panel and local bell
  • Tamper-resistant cover screw
  • Directional notched cover indicates flow direction from multiple viewing angles

Key Specs (both types):

  • Contact Rating: 10A @125/250VAC | 3A @24VDC
  • Flow Rate: 15 to 37.8 L/min (4 to 10 gpm)
  • Static Pressure Rating: 31 bar (450 psi)
  • Operating Temperature Range: 32°F to 155°F (0°C to 68°C)
  • Shipping Weight: 1kg
  • Compatible Pipe: Steel pipe, schedule 10 through 40

VTWS (Saddle Type) – Model Range:

Model Nominal Pipe Size Rated Working Pressure
VTWS50 50mm (2") 31 bar (450 psi)
VTWS65 65mm (2½") 31 bar (450 psi)
VTWS80 80mm (3") 31 bar (450 psi)
VTWS100 100mm (4") 31 bar (450 psi)
VTWS125 125mm (5") 31 bar (450 psi)
VTWS150 150mm (6") 31 bar (450 psi)
VTWS200 200mm (8") 15.5 bar (225 psi)

VTWT (Threaded Type) – Model Range:

Nominal Size Threaded (in) Tee Depth (in)
DN25 (1") 1 x 1 x 1 2⅛
DN32 (1¼") 1¼ x 1¼ x 1
DN40 (1½") 1½ x 1½ x 1
DN50 (2") 2 x 2 x 1

Note: Common and B-NO connections close when the vane is deflected (i.e., when water is flowing). Dual switches permit combined applications on a single detector.

View
,

Emergency Exit Lights

4.00 out of 5

Fire Exit Signs, also known as Fire Escape Route Signs, must be visible even when the power supply fails. Illuminated fire escape route signs and fire exit signs fulfil this requirement. The minimum backup duration of emergency lighting as specified by regulations is generally between 1 and 3 hours.EXit lights comes in various models.Refer the data sheet for more information.

View
,

Emergency Lights

0 out of 5

Emergency lighting is a very important element of Means of Escape from fire and must be installed in accordance with the British Standard Specification BS 5266 : Part 1 : 1999 - Code of Practice for Emergency Lighting. It is important that it is installed by a trained engineer who is familiar with the British Standard. There are basically two types of emergency lighting systems: Maintained and Non maintained. In maintained systems, individual luminaries each incorporate a battery that is charged from the mains lighting supply. For example, when the mains power is fully restored following an interruption, the luminaries emergency lighting battery is fully recharged from the mains power supply. In a non-maintained system individual luminaries incorporate a power back up supply independent of the mains supply. At present, maintained luminaries are only required in areas where the lighting is dimmed e.g. cinemas and theatres etc.

View
,

Alarm Bell

0 out of 5

The FG0218 is a robust, LPCB-certified 24VDC motorised fire alarm bell delivering a powerful 93 dB audible alert for conventional fire alarm systems. Built to EN54-3 Type A standards, it combines high sound output with ultra-low current consumption — making it an efficient and reliable notification device for commercial, industrial, and institutional applications.

Reliable & Interference-Free Fitted with two series diodes for built-in fault monitoring, the FG0218 is fully suppressed to prevent any interference with other equipment on the circuit. The acetral gear wheel and steel striker mechanism ensures consistent, dependable bell operation throughout the product's life.

Simple Installation A versatile multi-fixing base plate in moulded black polycarbonate allows straightforward mounting on virtually any surface type. Terminals accept cables up to 2.5mm² for easy wiring.

Key Specifications

  • Voltage: 24 VDC | Current: 25 mA
  • Sound Output: 93 dB @ 1m
  • Dimensions: Ø152mm × H56mm | Weight: 850g
  • Movement: Motor, pinion and steel striker
  • Gong: Steel, secured with Philips screw
  • Base Plate: Moulded black polycarbonate

Certifications: LPCB Certified | EN54-3 Type A Compliant

View
,

Smoke Detector - FG-S01

0 out of 5

The FGS01 is a reliable, battery-powered stand-alone photoelectric smoke detector designed for residential and small commercial use. Operating on the photocell principle, it continuously monitors the air for smoke particles produced by fire, providing early warning that gives occupants the vital seconds needed to evacuate and call emergency services.

Simple & Self-Contained Requiring no wiring or connection to a fire alarm control panel, the FGS01 is powered by a single 9V battery lasting at least one year under normal conditions. When the battery runs low, the detector gives an audible beep at 30–40 second intervals for a minimum of 7 days — providing ample warning before power is lost.

Easy to Test & Maintain A built-in test button allows weekly functional testing with a single press. The unit should be vacuumed regularly to remove dust particles from the detection chamber. The casing must not be opened during cleaning.

Recommended Placement For optimal protection, install at least one detector per room and one per floor, with particular attention to hallways, stairways, bedroom doors, living rooms, and storage areas containing electrical equipment. Avoid installation in damp spaces, near doors or windows, or in areas subject to temperature extremes (below 4°C or above 40°C).

Power & Battery

  • Power: 9V battery (recommended: Eveready #522/#1222, Duracell #MN1604, or Gold Peak #1604P/#1604S)
  • Battery Life: Minimum 1 year under normal use

View