OS&Y GATE VALVE FGO138-300
UL Listed and FM Approved resilient seated outside screw and yoke (OS&Y) gate valve with flanged x grooved end configuration, conforming to AWWA C515 and BS5163 with fusion bonded epoxy coating compliant with AWWA C550. The 300 PSI rated counterpart to the FGO138-365, offering the same flanged-groove connection flexibility across a full size range from 50mm (2") to 300mm (12") and compatible with a wide range of international connection standards.
Key Specs:
- Working Pressure: 300 PSI
- Working Temperature: -10°C to 120°C
- Valve Standard: AWWA C515 / BS5163 | Coating: AWWA C550
- Connection Ends: ANSI B16.1 Class 125 / B16.42 Class 150, EN1092-2 PN16, AWWA C606, VDS2100/AS2638.2
- Sizes: 50mm to 300mm (2" to 12")
- Approvals: UL Listed & FM Approved
Materials:
| Part | Material |
|---|---|
| Body | Ductile Iron (A536 65-45-12) |
| Wedge | Ductile Iron, EPDM Coated |
| Wedge Nut | Stainless Steel (AISI 304) |
| Stem | Stainless Steel (AISI 304/420) |
| Bonnet | Ductile Iron (A536 65-45-12) |
| Gasket | EPDM |
| Packing | PTFE (Non-asbestos) |
| Stem Nut | Bronze (ASTM B62) |
| Handwheel | Ductile Iron (A536 65-45-12) |
Flanged x grooved end configuration with rising OS&Y stem at 300 PSI — suits installations requiring transition between flanged and grooved pipework with broad international standard compatibility.
OS&Y GATE VALVE FGO907-250
UL Listed and FM Approved resilient seated outside screw and yoke (OS&Y) gate valve with flanged end connections, conforming to AWWA C515 and BS5163 with fusion bonded epoxy coating compliant with AWWA C550. The FGO907-250 covers the large diameter range from 350mm (14") to 600mm (24"), making it the ideal choice for major water mains, large-scale fire protection infrastructure, and industrial installations where high-flow isolation is required.
Key Specs:
- Working Pressure: 250 PSI
- Working Temperature: -10°C to 120°C
- Valve Standard: AWWA C515 / BS5163 | Coating: AWWA C550
- Connection Ends: ANSI B16.1 Class 125 / B16.42 Class 150, EN1092-2 PN16
- Sizes: 350mm to 600mm (14" to 24")
- Approvals: UL Listed & FM Approved
Materials:
| Part | Material |
|---|---|
| Body | Ductile Iron (A536 65-45-12) |
| Wedge | Ductile Iron, EPDM Coated |
| Wedge Nut | Stainless Steel (AISI 304) |
| Stem | Stainless Steel (AISI 304/420) |
| Bonnet | Ductile Iron (A536 65-45-12) |
| Gasket | EPDM |
| Packing | PTFE (Non-asbestos) |
| Stem Nut | Bronze (ASTM B62) |
| Handwheel | Ductile Iron (A536 65-45-12) |
Large diameter OS&Y flanged gate valve — suited to major fire protection mains and industrial water supply systems requiring high-flow isolation.
BALL VALVES
Fireguard produces various size of ball valves with UL approval These valves are forged brass body for high strength with brass ball with tenon seat and steel handle with vinyl insulation Sizes available from V." to 2" with female x female Ball type shut-off valves are for use with sprinkler systems, dry sprinkler systems, standpipe systems and manual deluge control valves.
PHOTO ELECTRIC SMOKE & HEAT DETECTOR
The FG318 and FG323 are LPCB-certified conventional photoelectric smoke and heat detectors designed to respond reliably across a wide spectrum of fire types. Factory tested and calibrated for high accuracy and low false alarm rates, they combine advanced detection technology with a sleek, low-profile design that suits any commercial or residential installation.
Two Detection Technologies, One Consistent Platform The FG318 uses advanced photoelectric smoke detection technology, offering a coverage area of up to 100 m² per detector. The FG323 is a conventional heat detector covering up to 50 m². Both share the same compact form factor and dual 360° LED indicators, ensuring consistent visual alarm confirmation from any viewing angle.
Flexible Wiring Options Available in 2-wire and 2-wire with LED variants, with a selectable N/C (normally closed) or N/O (normally open) relay output — providing the flexibility to suit a wide range of conventional fire alarm panel configurations. Detector sensitivity is programmable via the FACP.
Key Specifications
- Operating Voltage: 12V
- Smoke Sensitivity: EN54-5/7:2000 standard
- Detection Range: 100 m² (smoke) / 50 m² (heat)
- Start-Up Current: 70 µA max
- Alarm Indicator: Red LED, continuously lit
- Reset Voltage: Less than 1V | Reset Time: Less than 1 second
- Remote Output: 15 mA max, diode gate
- Operating Temperature: -10°C to +50°C
- Humidity: 0–95% RH (non-condensing)
- Dimensions: Ø100mm × H46mm (with base) | Weight: 130g
Models Available
- FG318-2 — 2 Wire Optical Smoke Detector
- FG318-2L — 2 Wire Optical Smoke Detector with LED
- FG323-2 — 2 Wire Heat Detector
- FG323-2L — 2 Wire Heat Detector with LED
Certifications: LPCB Certified | EN54-5/7:2000 Compliant
PRE ACTION SYSTEM
Pre action System with Electric/ Pneumatic Release is generally used to protect water sensitive areas such as computer rooms, storage areas of valuable articles, to avoid water damage due to damaged sprinklers or damaged sprinkler piping. Preaction System is also effectively used to have Pre-alarm of a possible fire condition and allows time to extinguish fire by hand held fire extinguishing equipment, prior to water discharge through sprinkler heads. It uses an automatic sprinkler with supplemental detection system. In the event when fire cannot be extinguished by hand held fire extinguishing equipment, the increase in temperature will open one or more sprinkler heads to discharge water. Model:
- Single Interlock Preaction with Electric Release
- Single Interlock Preaction with Dry Pilot Actuation
- Single Interlock Preaction with Wet Pilot Actuation
- Double Interlock Preaction with Electric/Electric Release
- Double Interlock Preaction with Electric/Pneumatic Release
PRESSURE GUAGE
High-quality pressure gauges specifically designed for Fire Sprinkler Services. Model FGP-1 features a corrosion-resistant polished stainless-steel case and bezel with brass wetted parts, ideal for standard applications. Model FGP-2 is equipped with Monel internals and glycerin filling, making it suitable for sea water applications. Both models feature dual-scale dials (KG/SQCM and PSI) with hardened glass windows for durability and clear visibility.
Technical Specifications
|
Feature |
Model FGP-1 |
Model FGP-2 |
|---|---|---|
|
Dial Size |
90mm (3.5") |
100mm (4") |
|
Pressure Range |
0 to 21 kg/sqcm0 to 300 PSI |
0 to 21 kg/sqcm0 to 300 PSI |
|
Burdon Tube & Wetted Parts |
Phosphor Bronze Burdon Tube & Brass moving part |
Monel |
|
Dial Type |
White background black graduation scale with dual reading in kg/sqcm and PSI |
White background black graduation scale with dual reading in kg/sqcm and PSI |
|
Case and Bezel |
Polished Stainless Steel Case with positive seal against weather, moisture & dust |
Polished Stainless Steel Case, Glycerine filled |
|
Mounting |
Direct |
Direct |
|
Window |
Hardness Glass |
Hardness Glass |
|
Accuracy |
+/- 2% of FSD for the middle half of scale |
+/- 2% of FSD for the middle half of scale |
|
Connection |
1/4" BSPT |
1/4" BSPT |
|
Approvals |
FGP-1, FGP-2 FM Approved |
FGP-1, FGP-2 FM Approved |
|
Reference Standards |
FM Standards, NFPA-13 |
FM Standards, NFPA-13 |
Key Features
- Model FGP-1: Corrosion-resistant stainless steel construction for standard fire sprinkler applications
- Model FGP-2: Monel internals with glycerin filling for enhanced performance in sea water environments
- Dual-scale pressure readings (KG/SQCM and PSI)
- Hardened glass window for durability
- FM Approved (Model FGP-2)
- Compliant with FM Standards and NFPA-13
Installation & Maintenance Guidelines
⚠️ CAUTION:
- Do not over tighten the gauge
- Do not tighten the gauge by holding the dial - always use a spanner on the socket square
- Mount using the square provided for spanner grip, not by turning the case
- Use PTFE tape around male threads for sealing
- Mount in vertical position and isolate with valve or cock
- Do not install visibly damaged gauges
- Inspect regularly for corrosion or damage
- Calibrate periodically as per NFPA/TAC requirements or local authority jurisdiction
Note: Pressure gauges are mass calibrated; individual calibration certificates are not provided. Store and ship in original packaging for best results.
Ordering Information: Specify connection type and model when ordering.
BREECHING INLET VALVE
The Fireguard FG08 series breeching inlet valves are BSI-certified dry riser inlet assemblies fully compliant with BS5041 Part 3, designed to provide ground-level water supply connection points for dry rising main systems. When positioned as close as possible to the rising main, they minimise pressure loss — a critical consideration in high-rise building firefighting operations where the fire brigade charges the system in an emergency.
Two Configurations for Different Flow Requirements
The FG08-202-00 2-way inlet breeching provides two 2½" instantaneous male BS336 non-return valve inlets with a 4" outlet flange, suited to buildings with moderate riser flow requirements.
The FG08-203-00 4-way inlet breeching provides four 2½" instantaneous male non-return valve inlets with a 6" outlet flange, delivering higher flow capacity for larger or taller high-rise buildings.
Both models are supplied complete with a 1" drain valve and plastic blank caps for inlet protection when not in use.
Robust Construction Bodies are cast from ductile iron to BS EN 1563:1997, with universal PN16 flange copper alloy inlets to BS EN 12163:1998 and male instantaneous copper alloy outlets to BS336/BS EN 12163:1998 — ensuring long-term durability and compatibility across all standard UK fire brigade connections.
Key Specifications
- Body: Ductile cast iron BS EN 1563:1997
- Working Pressure: 20 bar | Test Pressure: 30 bar
- Inlet: Universal Flange PN16 Copper Alloy (BS EN 12163:1998)
- Outlet: Male instantaneous BS336 Copper Alloy (BS EN 12163:1998)
- Blank Cap: Plastic
- 2-Way: 2 × 2½" inlets / 4" outlet flange
- 4-Way: 4 × 2½" inlets / 6" outlet flange
Certifications: BSI Certified | BS5041 Part 3 Compliant
BREECHING INLET CABINET
The breeching inlet cabinets are manufactured strictly in accordance with BS 5041 : Part 5 : 1974.
Specification
- 1 Compact and elegant design.
- Quality finishes in epoxy/polyester powder coated and oven baked.
- Easy installation with pre-cut flange holes at the rear panel.
- Material option: M.S steel painted Red, Stainless steel
RATIO CONTROLLER
UL Listed wafer-style ratio controller designed for accurate foam concentrate proportioning across a wide range of flow rates and pressures. Operating on the venturi principle, the Ratio Controller introduces foam concentrate into the water stream by creating a low-pressure zone at the inlet nozzle, automatically adjusting concentrate flow as system demand varies.
Compatible with Bladder Tank Proportioning Systems, Inline Balance Proportioning Systems, and Skid Mounted Pump Balance Proportioning Systems, the FGRC series offers a reliable and passive proportioning solution with no moving parts requiring external power.
Key Specs:
- Models: FGRC-B (Bronze) | FGRC-S (Stainless Steel)
- Sizes: 65NB, 80NB, 100NB, 150NB
- Operating Pressure: 2.1 to 12 Bar
- Max Service Pressure: 14 Bar (200 PSI)
- Factory Hydro Test: 25 Kg/sq.cm (350 PSI)
- Mounting: Between ANSI B16.5 – 150# flanges
- Finish: Red RAL 3000 or Natural Finish
- Approval: UL Listed
Flow Range (AFFF 3%):
| Size | AFFF 3% (LPM) | AR-AFFF 3/3% (LPM) |
|---|---|---|
| 65NB (2½") | 100 to 1,550 | 380 to 500 |
| 80NB (3") | 260 to 3,000 | 680 to 2,900 |
| 100NB (4") | 650 to 6,000 | 1,400 to 5,800 |
| 150NB (6") | 1,200 to 12,000 | 2,750 to 11,600 |
Requires a minimum of five pipe diameters of straight unobstructed pipe upstream and downstream. Flow range quoted for AFFF 3% — contact us for other foam concentrate types.
Relay Module IQ611MR
The IQ611MR is an intelligent addressable relay module designed to extend the control capabilities of fire alarm systems. Providing two simultaneously activated relay output sets, it takes a single address on the Signaling Line Circuit (SLC) or Data Communication Link (DCL) of the fire alarm control panel — enabling precise, programmable control of auxiliary devices such as door holders, fans, lifts, and other building systems.
Clear Status Indication A red LED provides continuous visual feedback on the module's status. During normal operation it blinks every 4 seconds; when an event is activated, the LED blinks at an extended rate to indicate the active condition, returning to normal once the event clears.
Flexible Installation Compatible with both Class A/DCLA and Class B/DCLB circuit configurations, the IQ611MR mounts directly onto a standard 2×4 or 4×4 electrical box using the IQ611B surface wall box. Wiring is straightforward with 12–18 AWG wire.
Key Specifications
- Nominal Voltage: 24 VDC (Range: 15–28 VDC)
- Standby Current: 0.15 mA | Active Current: 0.26 mA
- Contact Rating: 30 VDC, 2A
- Operating Temperature: 0°C to 50°C (32°F to 122°F)
- Operating Humidity: 0–93% RH
- Dimensions: 120 × 120 × 45 mm | Weight: 255g
- Wiring: 12–18 AWG
Certifications: UL Listed (UL864) | FM Approved
REMOTE INDICATING LAMP
This unit is designed to ensure that alarm signal can be actually transmitted to all locations in order to prevent any missing signal caused by separated zones. Especially for the closed room, any fire condition happened can be trans mitted to outside for pre-fire alarm notification.
REMOTE LED INDICATOR
The IQ661-RI is a UL-listed remote LED indicator designed to provide clear, at-a-glance visual status indication for connected fire alarm modules. Purpose-built as a companion accessory to the IQ611MM Mini Input Module, it must be installed in the same room as the IQ611MM to ensure local visual confirmation of device status is always available to occupants and responders.
Simple, Effective Visual Indication The IQ661-RI mirrors the status of its connected device, providing a visible alert when the associated module registers an alarm, supervisory, trouble, or monitor event. Its compact, low-profile design allows it to be neatly mounted into a standard 2×4 electrical box with minimal intrusion.
Easy Installation The module mounts directly into a standard electrical box and wires to the compatible device following the installation manual of that device — no complex configuration required.
Key Specifications
- Active Current: 2 to 5 VDC
- Nominal Voltage: 6.5 mA max
- Operating Temperature: 0°C to 49°C (32°F to 120°F)
- Operating Humidity: 0–93% RH
Certifications: UL Listed