ADDRESSABLE EMERGENCY EXIT SIGN FG-T741R/G

0 out of 5

Specification

  • Model: FG-T741R/G
  • Input Voltage AC120V/0.038A or AC277/0.018A 50/60Hz
  • AC Power 3.5W
  • Battery Ni-MH Battery: AA 600MAH/4.8V
  • Emergency 3Hours Duration
  • LED 8 pcs Ф5 Red or Green
  • Communication 485 BUS BUS

View

ADDRESSABLE EMERGENCY LIGHTS

0 out of 5

Specification

  • Model: FG-T632L / FG-T604L
  • Voltage AC120V/0.05A or AC2277/0.025A 50/60Hz
  • AC Power 5.5W Battery Ni-MH SC 2200MAH/4.8V
  • Emergency 3Hours Duration LED 20pcs SMD2835 
  • Communication 485 BUS BUS

View

IQ600 Addressable Fire Alarm Control Panel

0 out of 5

Fireguard IQ600 is an Addressable Fire Alarm Control Panel designed for small to medium-scale facilities. It is ideally suited for both new and retrofit commercial, institutional, and industrial fire detection and notification applications. IQ600 is a state‐of‐the‐art addressable fire control system that meets the requirements of UL864 10th. It supports up to 4 Addressable Signaling Line Circuits of 252 addressable devices/points per loop. It also has a capacity of 2 to 10 Notification Appliance Circuits and 4+1 form C dry relay contacts (4 relays are used for Fire Department connection). The IQ600 has a 7’’ LCD with 800 X 480 resolution, 6 auxiliary function keys, and 9 LED indicators making it a highly intuitive fire alarm user interface. It can be connected to 109 remote Panels and Annunciators via an external network to form a fire emergency detection and notification network system.


Features
  • 1, expandable to 4, intelligent Signaling Line Circuit: (SLC) Class A or B, with no limit on the number of zones.
  • Up to 252 detectors and devices: modules, addressable call point or addressable horn strobe per SLC; up to 1008 detectors and devices per Fire Alarm Control Panel (FACP)
  • Automatic addressing function: In Automatic mode, the panel sequentially assigns addresses from 1 to 252 to loop devices.
  • Loop spots can be any mix of detectors, module, call point or addressable horn strobe.
  • PC configuration software.
  • In "walk test mode" detectors are triggered to alarm by an aerosol generator and the linked alarm devices are triggered simultaneously.
  • Loop break locating: The panel will display the loop and point address where the break has occurred.
  • 7 LCD with 800 x 480 resolution.
  • 4+1 form C dry relay contacts (4 relays are used for Fire Department connection, non-programmable), 1 programmable relay.
  • 6 programmable auxiliary function keys
  • 9 LED indicators, making it a highly intuitive fire alarm user interface.
  • Standard network for up to 109 nodes (The sum of panel and annunciator is not more than 109).
  • Connection with one IQI 51 digital communication panel with IQ600E network card.
  • RJ45 and RS232 interface available for output to third-party monitoring software
  • Max. 5000 event log and compatible with EPSON LX350 printer

View

IQ601 Addressable Fire Alarm Control Panel

0 out of 5

Fireguard IQ601 is an Addressable Fire Alarm Control Panel designed for small to medium-scale facilities. It is ideally suited for both new and retrofit commercial, institutional, and industrial fire detection and notification applications IQ601 is a state‐of‐the‐art addressable fire control system that meets the requirements of UL864 10th edition. It supports 1 Addressable Signaling Line Circuits of 252 addressable devices/points. It also has a capacity of 2 to 4 Notification Appliance Circuits and 4+1 form C dry relay contacts (4 relays are used for Fire Department connection). The IQ601 has a 7’’ LCD with 800 X 480 resolution, 6 auxiliary function keys, and 9 LED indicators, making it a highly intuitive fire alarm user interface. It can be connected to 109 remote Panels and Annunciators via an external network to form a fire emergency detection and notification network system. Chassis in red and grey colors are provided. Order the preferred color following the ordering information table


Features
  • 1 intelligent Signaling Line Circuit (SLC) Class A or B, with no limit on the number of zones.
  • Up to 252 detectors and devices (modules, addressable call point, or addressable horn strobe per SLC;
  • Automatic addressing function: In Automatic mode, the panel sequentially assigns addresses from 1 to 252 to loop devices. Loop spots can be any mix of detector, module, call point, or addressable horn strobe
  • PC configuration software.
  • In "walk test mode" detectors are triggered to alarm by an aerosol generator, and the linked alarm devices are triggered simultaneously.
  • Loop break locating: The panel will display the loop and point address where the break has occurred.
  • 7 LCD with 800 x 480 resolution.
  • 4+1 form C dry relay contacts (4 relays are used for Fire Department connection, non-programmable), 1 programmable
  • 6 programmable auxiliary function keys
  • 9 LED indicators, making it a highly intuitive fire alarm user interface.
  • Standard network for up to 109 nodes (The sum of panel and annunciator is not more than 109).
  • Connection with one IQI 51 digital communication panel with IQ600E network card.
  • RJ45 and RS232 interface available for output to third-party monitoring software.
  • 5000 event log and compatible with EPSON LX350 printer

View

IQ605 Addressable Fire Alarm Control Panel

0 out of 5

The IQ605 is an advanced addressable Fire Alarm Control Panel engineered for small to medium-sized commercial, institutional, and industrial facilities. Fully compliant with UL 864 10th edition, it is equally suited for new builds and retrofit applications, delivering powerful, scalable fire detection and notification in a modular design.

Intelligent Detection & Scalable Capacity The IQ605 supports a single SLC loop accommodating up to 252 addressable devices, expandable to 4 loops for larger deployments. It handles up to 8 NACs (Class A or B), 5 Form C relay outputs, and connects to up to 109 remote panels or annunciators via CAN bus — making it a true hub for building-wide fire safety.

Intuitive Interface A vivid 7" colour LCD at 800×480 resolution, 9 LED indicators, 6 auxiliary function keys, and a built-in 30-zone LED/switch annunciator give operators instant, clear system visibility. Four levels of password protection ensure secure, role-based access.

Advanced Features

  • Automatic sequential device addressing
  • Positive alarm sequence to reduce false alarms
  • Two-stage operation support
  • Dual event logs: 1,000-alarm history and 5,000-event general log
  • USB port for programming and firmware upgrades
  • RJ45 and RS232 interfaces for third-party monitoring

Key Specifications

  • Primary Supply: 110–120 VAC or 220–240 VAC (50/60Hz)
  • Battery Backup: Up to two 40Ah sealed lead-acid batteries
  • Operating Temperature: 0°C to 49°C (32°F to 120°F)
  • Operating Humidity: Up to 93% @ 32°C (90°F)
  • Connections: 12–18 AWG
  • Mounting: Surface or semi-flush wall mount

Certifications: UL Listed (UL 864 10th Edition)

View

IQ600NB Nac Booster

0 out of 5

The IQ600NB is a state-of-the-art addressable Notification Appliance Circuit (NAC) Booster Panel built for small to medium-scale commercial, institutional, and industrial facilities. Fully compliant with UL 864 10th edition, it is equally suited for new installations and retrofit applications where additional notification power is needed.

Powerful, Flexible Notification Output The IQ600NB delivers 8 independently programmable NACs (Class A or B, 3A each, 10A total), giving installers the flexibility to tailor notification zones precisely to the building layout. Four Form C dry relay contacts provide additional outputs for indicating AC fail, battery fail, ground fault, and general system troubles.

Intelligent & Intuitive A 4" LCD with 128×32 resolution, 4 navigation buttons, 1 enter button, and 4 LED indicators provide a clear, easy-to-use interface. The panel is fully configurable from the front panel with password protection and occupies 9 addresses on the SLC loop.

Key Specifications

  • Primary Supply: 110–120 VAC or 220–240 VAC (50/60Hz)
  • Secondary Power: Two 12V 40AH max (external) / Two 12V 18AH max (cabinet)
  • Communication: SLC Class A & B / Pass Through Class A & B
  • Operating Temperature: 0°C to 49°C (32°F to 120°F)
  • Operating Humidity: Up to 93% @ 32°C (90°F)
  • Mounting: Surface or flush wall mount

Certifications: UL Listed (UL 864 10th Edition)

View

IQ600LA Remote LED Annunciator

0 out of 5

The IQ600LA LED Annunciator is used to display zone events from the fire alarm control panel. The IQ600LA comes with a lockable glass door. A sliding paper strip is used to show zone messages. The IQ600LA can show up to 30 zones (2 LEDs + 1 button / zone) for alarm/trouble events display & control. lt also comes with 35 zones (2 LEDs / zone) for alarm/trouble events display. The LED annunciator includes separate status LEDs for power, general trouble, signal silence status, and ground fault. It also comes with push buttons to operate local buzzer silence, signal silence, events reset, and self-test. The IQ600LA is connected to the IQ600/IQ601 series panels via the external CAN network and it is powered by an external 24 VDC power source from the panel. The network can include up to a maximum of 20 remote LED annunciators.


Features
  • 7” color LCD and a resolution of 800 X 480
  • Events are displayed in different colors
  • 6 function keys and 5 navigation keys
  • 109 annunciators supported in the system
  • 9 LED indicators and intuitive fire-alarm user interface
  • Display annunciate up to 8 zones simultaneously
  • Access door with lock
  • *For indoor installation only

View

IQ600RA Remote Annunciator

0 out of 5

The IQ600RA is a UL-listed remote LCD annunciator designed to extend the monitoring and control capabilities of the Fireguard IQ600/IQ601 Fire Alarm Control Panel. With a vivid 7" colour touchscreen display and an intuitive interface, it puts full system visibility exactly where it's needed most.

Clear, Intuitive Control The IQ600RA features a 7" colour LCD at 800×480 resolution, 6 auxiliary function keys, and 9 LED indicators, delivering a comprehensive and easy-to-read fire alarm interface for building staff and emergency responders. Available in both surface and flush mounting configurations.

Scalable Network Architecture Up to 110 annunciators or 110 panels can be interconnected via CAN bus (Class B), forming a building-wide or campus-wide fire detection and notification network — all linked back to the IQ600/IQ601 FACP.

Key Specifications

  • Operating Voltage: 24 VDC (powered by panel auxiliary output)
  • Standby / Alarm Current: 170 mA / 173 mA
  • Operating Temperature: 0°C to 49°C (32°F to 120°F)
  • Operating Humidity: Up to 93% @ 32°C (90°F)
  • Weight: 2.9 kg | Colour: Red | Location: Indoor dry

Certifications: UL Listed (UL 864)

View

Addressable Manual Pull Station IQ621

0 out of 5

The IQ621 is a professional-grade, UL-listed addressable manual pull station designed for intelligent fire alarm systems. Compliant with UL 38 standards for Fire Protective Signalling Systems, it meets ADA requirements with a maximum 5 lb activation force — ensuring accessibility and regulatory compliance across commercial, institutional, and public-use buildings.

Smart Activation, Instant Confirmation To trigger an alarm, simply lift the front cover and press the button. A red LED illuminates immediately upon activation to provide clear visual confirmation. A reset key is included with every unit for quick and easy service restoration.

Addressable & Flexible Unlike conventional pull stations, the IQ621 integrates directly into addressable fire alarm loops, enabling precise location identification at the control panel. It also features a normally closed or normally open dry contact, offering added flexibility for integration with third-party systems.

Built to Last Crafted from durable materials with solid construction, the IQ621 is engineered for reliable, long-term performance in demanding environments.

Key Specifications

  • Nominal Voltage: 24 VDC (Range: 15–28 VDC)
  • Standby Current: 0.1 mA
  • Alarm Current: 1 mA
  • Operating Temperature: 0°C to 49°C (32°F to 120°F)
  • Humidity: 0–93% RH
  • Dimensions (with base): 120 × 120 × 54 mm
  • Weight: 237 g
  • Dry Contact: Supplementary 30 VDC
  • Wiring: 12–18 AWG

Easy Installation Supports both Class A and Class B circuit configurations. Compatible with the IQ621B base and standard 2×4 or 4×4 electrical boxes for flexible mounting options.

Certifications: UL Listed (UL 38) | ADA Compliant

View

FG-EVAC Audio System

0 out of 5

EVAC Audio Systems provide voice communication. The Audio Controller has built in two amplifier 500 watt with backup and built in power supply charger 30 hours stand by + 30 minutes Evac. It continues to provide two simultaneous channels EVAC and Alert 10 minutes and optional 3 x balanced audio input + 2 Mixer. Digitized alarm tones and digitally recorded voice messages and message construction, and manages both multiple 8 button microphone zone inputs and 3 audio inputs with 1 Mixer and 2 message player and 6 audio output.


Features
  • Alarm/evacuation signal generation with multiple built-in tones
  • Standard or customized digital message storage and message generation
  • Automatic or manual operation
  • Mass Notification operation 1- 2 channels simultaneously and optional above 2 channels are available.
  • Audio systems provide dual channel operation
  • 3x audio balance Input and Dry contact to interface external Audio Source and MIC and 1x Mixer and 2 amplifier’s Mixer output
  • 1x Bus ACSI to interface 8 Voice alarm panel or 8x MIC or Mixed together up to 8 units.
  • Up 10 x500 Watt Amplifiers can connect in RS485 to distribute in a group of floors .
  • Each Amplifier support 6x Speakers zones to configure channel #1 EVAC and Channel #2 x Alert and phase evacuation other Speaker zones can be customised message.
  • 3 Dry contact relay 1. General Alarm 2. Emergency Evac 3.
  • Recorded Audio Messages can be import from USB
  • USB Back up and Restore
  • Backup Amplifiers 500Watt
  • Advanced integration Override output 24V, Attenuators, Flash light and 3rd party system
  • 6x Audio Output 24V for Attenuator and Flash Lights and 4 x Pre-Amplifier output
  • Fire Alarm integration with supervision
  • Speakers line supervision
  • Battery supervision
  • Wiring Method A+B
  • Wall Mount and Rack mount design

View

Conventional Manual Pull Station IQ632

0 out of 5

The IQ632 is a reliable, UL-listed conventional manual pull station designed for indoor fire alarm systems. Built to UL 38 standards for Fire Protective Signaling Systems, it meets ADA requirements with a maximum 5 lb activation force — making it accessible and code-compliant for a wide range of commercial and public buildings.

Simple to Activate, Easy to Reset In the event of a fire, simply lift the cover and press the button to trigger an alarm signal. A red LED illuminates instantly to confirm activation. Resetting the station is straightforward using the included switch key.

Built to Last Constructed from durable materials and solid components, the IQ632 is engineered for long-term, dependable performance in demanding environments.

Key Specifications

  • Operating Voltage: 12–33 VDC
  • Operating Current: 150 mA max.
  • Operating Temperature: 0°C to 49°C (32°F to 120°F)
  • Humidity: 0–93% RH (non-condensing)
  • Dimensions (with base): 120 × 120 × 54 mm
  • Weight: 237 g
  • Wiring: 12–18 AWG

Easy Installation Compatible with the IQ621B base and standard 2×4 or 4×4 electrical boxes, the IQ632 installs quickly with no polarity concerns on the terminal wiring.

Certifications: UL Listed (UL 38) | ADA Compliant

View