ADDRESSABLE EMERGENCY EXIT SIGN FG-T741R/G
Specification
- Model: FG-T741R/G
- Input Voltage AC120V/0.038A or AC277/0.018A 50/60Hz
- AC Power 3.5W
- Battery Ni-MH Battery: AA 600MAH/4.8V
- Emergency 3Hours Duration
- LED 8 pcs Ф5 Red or Green
- Communication 485 BUS BUS
ADDRESSABLE EMERGENCY LIGHTS
Specification
- Model: FG-T632L / FG-T604L
- Voltage AC120V/0.05A or AC2277/0.025A 50/60Hz
- AC Power 5.5W Battery Ni-MH SC 2200MAH/4.8V
- Emergency 3Hours Duration LED 20pcs SMD2835
- Communication 485 BUS BUS
IQ600 Addressable Fire Alarm Control Panel
Fireguard IQ600 is an Addressable Fire Alarm Control Panel designed for small to medium-scale facilities. It is ideally suited for both new and retrofit commercial, institutional, and industrial fire detection and notification applications. IQ600 is a state‐of‐the‐art addressable fire control system that meets the requirements of UL864 10th. It supports up to 4 Addressable Signaling Line Circuits of 252 addressable devices/points per loop. It also has a capacity of 2 to 10 Notification Appliance Circuits and 4+1 form C dry relay contacts (4 relays are used for Fire Department connection). The IQ600 has a 7’’ LCD with 800 X 480 resolution, 6 auxiliary function keys, and 9 LED indicators making it a highly intuitive fire alarm user interface. It can be connected to 109 remote Panels and Annunciators via an external network to form a fire emergency detection and notification network system.
Features
- 1, expandable to 4, intelligent Signaling Line Circuit: (SLC) Class A or B, with no limit on the number of zones.
- Up to 252 detectors and devices: modules, addressable call point or addressable horn strobe per SLC; up to 1008 detectors and devices per Fire Alarm Control Panel (FACP)
- Automatic addressing function: In Automatic mode, the panel sequentially assigns addresses from 1 to 252 to loop devices.
- Loop spots can be any mix of detectors, module, call point or addressable horn strobe.
- PC configuration software.
- In "walk test mode" detectors are triggered to alarm by an aerosol generator and the linked alarm devices are triggered simultaneously.
- Loop break locating: The panel will display the loop and point address where the break has occurred.
- 7 LCD with 800 x 480 resolution.
- 4+1 form C dry relay contacts (4 relays are used for Fire Department connection, non-programmable), 1 programmable relay.
- 6 programmable auxiliary function keys
- 9 LED indicators, making it a highly intuitive fire alarm user interface.
- Standard network for up to 109 nodes (The sum of panel and annunciator is not more than 109).
- Connection with one IQI 51 digital communication panel with IQ600E network card.
- RJ45 and RS232 interface available for output to third-party monitoring software
- Max. 5000 event log and compatible with EPSON LX350 printer
IQ601 Addressable Fire Alarm Control Panel
Fireguard IQ601 is an Addressable Fire Alarm Control Panel designed for small to medium-scale facilities. It is ideally suited for both new and retrofit commercial, institutional, and industrial fire detection and notification applications IQ601 is a state‐of‐the‐art addressable fire control system that meets the requirements of UL864 10th edition. It supports 1 Addressable Signaling Line Circuits of 252 addressable devices/points. It also has a capacity of 2 to 4 Notification Appliance Circuits and 4+1 form C dry relay contacts (4 relays are used for Fire Department connection). The IQ601 has a 7’’ LCD with 800 X 480 resolution, 6 auxiliary function keys, and 9 LED indicators, making it a highly intuitive fire alarm user interface. It can be connected to 109 remote Panels and Annunciators via an external network to form a fire emergency detection and notification network system. Chassis in red and grey colors are provided. Order the preferred color following the ordering information table
Features
- 1 intelligent Signaling Line Circuit (SLC) Class A or B, with no limit on the number of zones.
- Up to 252 detectors and devices (modules, addressable call point, or addressable horn strobe per SLC;
- Automatic addressing function: In Automatic mode, the panel sequentially assigns addresses from 1 to 252 to loop devices. Loop spots can be any mix of detector, module, call point, or addressable horn strobe
- PC configuration software.
- In "walk test mode" detectors are triggered to alarm by an aerosol generator, and the linked alarm devices are triggered simultaneously.
- Loop break locating: The panel will display the loop and point address where the break has occurred.
- 7 LCD with 800 x 480 resolution.
- 4+1 form C dry relay contacts (4 relays are used for Fire Department connection, non-programmable), 1 programmable
- 6 programmable auxiliary function keys
- 9 LED indicators, making it a highly intuitive fire alarm user interface.
- Standard network for up to 109 nodes (The sum of panel and annunciator is not more than 109).
- Connection with one IQI 51 digital communication panel with IQ600E network card.
- RJ45 and RS232 interface available for output to third-party monitoring software.
- 5000 event log and compatible with EPSON LX350 printer
IQ605 Addressable Fire Alarm Control Panel
Fireguard IQ605 is an Addressable Fire Alarm Control Panel designed for small to medium-scale facilities. It is ideally suited for both new and retrofit commercial, institutional, and industrial fire detection and notification applications. IQ605 is a state‐of‐the‐art addressable fire control system that meets the requirements of UL864 10th edition. It supports 1 Addressable Signalling Line Circuits of 252 addressable devices, 2 optional class B isolated output units available. It also has 4 Class A/B Notification Appliance Circuits expandable to 8 with the optional 4 NAC Class A/B unit. The panel has 4 form C dry relay contacts (4 relays are used for Fire Department connection). The IQ605 has a 7’’ LCD with 800 X 480 resolution, 6 auxiliary function keys, and 9 LED indicators making it a highly intuitive fire alarm user interface. It can be connected to 109 remote Panels and Annunciators via an external network to form a fire emergency detection and notification network system. It also has built in 30 zones switch/LED annunciator. Max 2 optional unit can be added.
IQ600NB Nac Booster
Fireguard IQ600NB is an Addressable NAC Booster Panel designed for small to medium-scale facilities. It is ideally suited for both new and retrofit commercial, institutional, and industrial fire detection and notification applications. IQ600NB is a state‐of‐the‐art addressable fire control system that meets the requirements of UL864 10th edition. It supports 2 communication types: via SLC and Pass Through. It also has a capacity 8 Notification Appliance Circuits and 4 form C dry relay contacts (4 relays are used for indicating general loop/system troubles). The IQ600NB has a 4’’ LCD with 128 X 32 resolution, 4 navigation buttons and 1 enter button, and 4 LED indicators making it a highly intuitive fire alarm user interface. It will take up 9 addresses on the SLC loop.
General Information
- LCD Display 4’’ LCD with 128 X 32 resolution, 4 navigation buttons and 1 ‘’enter’’ button, and 4 LED indicators.
- Flexible Outputs 8 NACs, Class A or B, 3Amps each, independently programmable and 4 form C dry relay contacts.
- Communication Supports 2 communication types: via SLC and Pass Through.
IQ600LA Remote LED Annunciator
The IQ600LA LED Annunciator is used to display zone events from the fire alarm control panel. The IQ600LA comes with a lockable glass door. A sliding paper strip is used to show zone messages. The IQ600LA can show up to 30 zones (2 LEDs + 1 button / zone) for alarm/trouble events display & control. lt also comes with 35 zones (2 LEDs / zone) for alarm/trouble events display. The LED annunciator includes separate status LEDs for power, general trouble, signal silence status, and ground fault. It also comes with push buttons to operate local buzzer silence, signal silence, events reset, and self-test. The IQ600LA is connected to the IQ600/IQ601 series panels via the external CAN network and it is powered by an external 24 VDC power source from the panel. The network can include up to a maximum of 20 remote LED annunciators.
Features
- 7” color LCD and a resolution of 800 X 480
- Events are displayed in different colors
- 6 function keys and 5 navigation keys
- 109 annunciators supported in the system
- 9 LED indicators and intuitive fire-alarm user interface
- Display annunciate up to 8 zones simultaneously
- Access door with lock
- *For indoor installation only
IQ600RA Remote Annunciator
The IQ600RA is an intelligent remote LCD annunciator designed to be used with the Fireguard series IQ600 and IQ601 control panels. The IQ600LA is connected to IQ600/IQ601 series panels via the external CAN network and it is powered by an external 24 VDC power source from the panel. Up to 109 IQ600RA remote annunciator can be connected. The LCD can display up to 8 events simultaneously. Users can browse more events by pressing the up/down buttons until the first or the last events message is reached. Events are displayed according to the following rules:
- Events priority: (1) Alarm, (2) Supervisory, (3) Trouble, (4) Other Signal (5) Output.
Features
- 7” color LCD and a resolution of 800 X 480
- Events are displayed in different colors
- 6 function keys and 5 navigation keys 109 annunciators supported in the system
- 9 LED indicators and intuitive fire-alarm user interface Display annunciate up to 8 zones simultaneously Access door with lock
- *For indoor installation only
Addressable Manual Pull Station IQ621
The IQ621 Addressable Manual Stations are UL listed devices according to UL 38 for Fire Protective Signalling Systems for indoor use, and also meet ADA 5LB. maximum manual force. It is a normally open initiating device made from durable materials and solid parts for long-lasting performance. In case of fire, an alarm signal is generated by lifting the front cover and pushing the plate with the button. A red LED is visible on the station when the fire alarm signal is activated. A reset key (included) with the manual station. It also has a normally closed or normally open dry contact.
FG-EVAC Audio System
EVAC Audio Systems provide voice communication. The Audio Controller has built in two amplifier 500 watt with backup and built in power supply charger 30 hours stand by + 30 minutes Evac. It continues to provide two simultaneous channels EVAC and Alert 10 minutes and optional 3 x balanced audio input + 2 Mixer. Digitized alarm tones and digitally recorded voice messages and message construction, and manages both multiple 8 button microphone zone inputs and 3 audio inputs with 1 Mixer and 2 message player and 6 audio output.
Features
- Alarm/evacuation signal generation with multiple built-in tones
- Standard or customized digital message storage and message generation
- Automatic or manual operation
- Mass Notification operation 1- 2 channels simultaneously and optional above 2 channels are available.
- Audio systems provide dual channel operation
- 3x audio balance Input and Dry contact to interface external Audio Source and MIC and 1x Mixer and 2 amplifier’s Mixer output
- 1x Bus ACSI to interface 8 Voice alarm panel or 8x MIC or Mixed together up to 8 units.
- Up 10 x500 Watt Amplifiers can connect in RS485 to distribute in a group of floors .
- Each Amplifier support 6x Speakers zones to configure channel #1 EVAC and Channel #2 x Alert and phase evacuation other Speaker zones can be customised message.
- 3 Dry contact relay 1. General Alarm 2. Emergency Evac 3.
- Recorded Audio Messages can be import from USB
- USB Back up and Restore
- Backup Amplifiers 500Watt
- Advanced integration Override output 24V, Attenuators, Flash light and 3rd party system
- 6x Audio Output 24V for Attenuator and Flash Lights and 4 x Pre-Amplifier output
- Fire Alarm integration with supervision
- Speakers line supervision
- Battery supervision
- Wiring Method A+B
- Wall Mount and Rack mount design
Non-Addressable Manual Pull Station IQ632
The IQ632 Non-addressable Manual Stations are UL listed devices according to UL 38 for Fire Protective Signaling Systems for indoor use, and also meet ADA 5lb. maximum manual-force. It is normally open initiating device made from durable materials and solid parts for long lasting performance. In case of fire, an alarm signal is generated by lifting the cover and pushing the button. A red LED is visible on the station when the fire alarm signal is activated. A switch key (included) resets the station.
FG901CP AP Fire Control Panel
FG901CP_AP is a microprocessor fire control panel that allows fire detection by means of cabled or wireless devices, and it can be programmed and consulted from a touchscreen display
Features
- Multiprotocol control panel, with its minimal set-up it is able to manage open or closed loops of 240 compatible devices.
- Basic configuration can be expanded adding two loops each time to control up to 2160 devices, both optical and thermical, from a single control panel.
- In complex applications, it can be installed in a ring network (up to 128 control panels). In this distributed architecture, areas and zones can be monitored by detectors and they can be combined by means of logical expressions in order to trigger events for the panel to which they belong or for other panels of the ring network.
- With the installation of dedicated cards, it is also possible to connect the control panel to external peripheral, such as keyboards and LED panels.
- Certified UNI EN 54-2 e 54-4 for fire detection and report, this control panel provides three different access levels according to the user (installer, safety responsible and final user).
- The touch interface, simple and ergonomic, permits to any user to interact intuitively without training time and costs.
- The configuration procedure is immediate, auto programming and auto-addressing mechanisms allow to recognize, consult and program the devices on the field in a fast, systematic and correct way.
- The control panel can be programmed locally or from remote, by means of the dedicated online platform OneCloud, data can be exported and imported with any USB key.
- Monitoring is made possible thanks to WINWATCH32 supervision system.
- Detectors and devices diagnostics are carried on directly from the control panel, and a single operator is able to perform autonomously all the test procedures, and to check implant operativity of all its components.
- Regular maintenance interventions can be optimally planned and executed.
- Diagnostic data and historical data stored by the control panel can be easily exported and analysed.
- Control panel can be customized for any installation condition: colour, display background, programmable LED colour, logo displayed in welcome screen and the language can be selected as preferred.