,

MEDUIM VELOCITY NOZZLE

0 out of 5

The Medium Velocity Water Spray Nozzles are open type (non-automatic nozzles, designed for directional spray application in fixed fire protection system.

View

Mini Input Module IQ611MM

0 out of 5

The IQ611MM Input Module is designed to be inserted into a single gang utility box next to the dry contact device that it is monitoring. The IQ611MM input module monitors a single contact. The input line is monitored for open line faults and ground faults, and the contact must thus be wired with an end-of-line resistor. It is an intelligent addressable module and takes one address on the Signaling Line Circuit (SLC) or Data Communication Link (DCL) of the fire alarm control panel. The IQ611MM is a UL listed device according to UL864 for Fire Protective Signaling Systems for indoor use. The type of input contact is configurable. A remote red LED indicator is used to show the module’s status.

View
,

Mobile CO2 Extinguishers

0 out of 5

Fireguard Mobile CO2 gas fire extinguishers are highly effective against fires involving electrical equipment like computers, photocopiers and generators. Carbon dioxide trolley with special discharge hose and horn to use in high reach hazardous area is also available. Fireguard Mobile CO2 Extinguishers are suitable to use the areas like Flammable liquid storage, Food storage and processing plants, Airports, Telephone equipment rooms, Data processing centres, Engine rooms, Chemical plants and laboratories, Quench tanks, Petrochemical industries, Spray booths, etc.


Features
  • Cylinders are made of seamless carbon-manganese pipes which have high mechanical properties.
  • Cylinder designed to withstand high pressure and tested at 250 bar.
  • High-grade brass head valve ensures reliability and optimizes efficiency.
  • Head valves are either lever operated or rotary operated.
  • Unbreakable rising pipe made of aluminium to ensure long lasting life.
  • High gloss polyester powder painted uv stabilized after shot-blasting ensures corrosion resistance under extreme condition.
  • Safety valve is fitted in each extinguisher for maximum safety.
  • Discharge nozzle designed to produce a jet of extinguishing gas.

View

MULTIPLE JET CONTROL VALVE

0 out of 5

Multiple Control Valve does have a thermally actuated release element, which detects the fire and directs the water flow to a selected area water or to give sprinkler alarm. The multiple control valve is used to protect high risk, small areas within the building. The water under pressure is maintained at the inlet and up to the seat of the multiple jet control valve. On detection of fire the bulb breaks and the water under pressure lifts the clapper Valve. The valve must be used in a system that had a minimum 2 bar pressure. The valve must be inspected periodically. The release element should not be painted. The valve once actuated must be sent to the factory for the actuation mechanism and the seat must be replaced.

View
,

NRS GATE VALVE FGN105-300

0 out of 5

Resilient Seated NRS Type-Flanged-Groove Ends

View
,

NRS GATE VALVE FGN108-300

0 out of 5

Resilient Seated NRS Type-Flanged-Groove Ends

View
,

NRS GATE VALVE FGN909-250

0 out of 5

Resilient Seated NRS Type-Flanged-Ends

View
,

NRS GATE VALVE FGN909-300

0 out of 5

Resilient Seated NRS Type-Flanged-Ends

View
,

OS&Y GATE VALVE FGO135-300

0 out of 5

Resilient Seated OS&Y Type-Groove-Groove Ends

View
,

OS&Y GATE VALVE FGO138-300

0 out of 5

Resilient Seated OS&Y Type-Flanged-Groove Ends

View
,

OS&Y GATE VALVE FGO907-250

0 out of 5

Resilient Seated OS&Y Type-Flanged Ends

View
,

OS&Y GATE VALVE FGO907-300

0 out of 5

Resilient Seated OS&Y Type-Flanged Ends

View