EMERGENCY EXIT SIGN FG-74112G/R
Specification
- Input: AC120V/277V 50/60Hz
- Wattage: 3W
- Battery: Ni-Cd AA 4.8V/500mAh
- Emergency Duration: ≥ 3 Hours
- Lighting Source: 8pcs LEDS
- Lumen: >8cd/m²
- Type: Maintain
- Material:
- Aluminum Housing +Acrylic panel
EMERGENCY EXIT SIGN FG-741A12
Specification
- Input: AC120V0.034A 50/60Hz or AC347V/0.01A 50/60Hz
- Wattage: 5.5W
- Battery: Ni-Cd AA 3.6V/2000mAh
- Emergency Duration: ≥ 3 Hours
- Lighting Source: SMD2835 20pcs
- Lumen: 270 lm
- Type: Maintain
- Material: Aluminum Housing + Acrylic panel
EMERGENCY LIGHT FG-604ML
Specification
- Input: AC100V/240V 50/60Hz
- Wattage: 5.5W
- Battery: Ni-Cd AA 3.6V/2000mAh
- Emergency Duration: ≥ 3 Hours
- Lighting Source: SMD2835 20pcs
- Lumen: 204 lm
- Type: Maintain
EMERGENCY LIGHT FG-632ML
Specification
- Input: AC100V/240V 50/60Hz
- Wattage: 5.5W
- Battery: Ni-Cd AA 3.6V/2000mAh
- Emergency Duration: ≥ 3 Hours
- Lighting Source: SMD2835 20pcs
- Lumen: 270 lm
- Type: Maintain
EMERGENCY LIGHT MONITORING SYSTEM
The emergency lighting testing and monitoring system is designed to test, maintain and manage independent powering emergency lights. Capable of automatic testing, data analysis and result judgment, this system improves the maintainability of emergency lights, thus increasing their reliability.
Features
- The Emergency Lighting Monitoring Control Panel has a 7-inch colorful touch screen, offering excellent man-machine interaction experience.
- Controlled by sound and light, the integrated controller automatically conducts real-time and efficient testing and inspection of operating states and faults of emergency lights. Events will be recorded and history can be retrieved.
- Logs can be displayed. History events can be viewed on the screen and imported into the computer.
- Timed automatic testing, which can test lights emergency functions according to the set time period.
- Timed battery maintenance, which can charge and discharge batteries according to the set time period so as to prolong the battery life.
- Emergency Lighting Monitoring Control Panel and interfaces are connected by CAN bus(The communication distance is up to 1Km). The interface and its subordinate devices are connected by RS485 bus (The communication distance is up to 1Km). The layout is simple and the cost is low.
- Maximum 64 interfaces within a Emergency Lighting Monitoring Control Panel, with each interface connecting up to 254 devices, Up to 16,320 devices can be managed simultaneously.
EMERGENCY LIGHTS FG-682L
Specification
- Voltage: AC120V/227V 50/60Hz
- AC power: 6W
- Battery: Lead-Acid 6V 4.5Ah
- Emergency Duration: ≥ 3 Hours
- Lighting Source/Power: LED 2*3.2V/2W
- Light Level: 10.8Lux
- Qty/20GP: 6240pcs
EMERGENCY LIGHTS FG-601L
Specification
- Voltage: AC120V/227V 50/60Hz
- AC power: 7W
- Battery: Ni-Cd 3.6V 4.5Ah
- Emergency Duration: ≥ 3 Hours
- Lighting Source/Power: LED/20pcs 5050LED
- Luminance: >1 FC at 2.2m high
- Qty/20GP: 7080pcs
EMERGENCY LIGHTS FG-680L
Specification
- Voltage: AC120V/227V 50/60Hz
- AC power: 6W
- Battery: Lead-Acid 6V 4.5Ah
- Emergency Duration: ≥ 3 Hours
- Lighting Source/Power: LED 2*3.2V/2W
- Light Level: 10.8Lux
- Qty/20GP: 3930pcs
EMERGENCY LIGHTS FG-604L
Specification
- Voltage: AC120V/227V 50/60Hz
- AC power: 7W
- Battery: Ni-Cd 3.6V 4.5Ah
- Emergency Duration: ≥ 3 Hours
- Lighting Source/Power: LED/20pcs 5050LED
- Luminance: >1 FC at 2.2m high
- Qty/20GP: 5970pc
EMERGENCY LIGHTS FG-632L
Specification
- Voltage: AC120V/227V 50/60Hz
- AC power: 7W
- Battery: Ni-Cd 3.6V 4.5Ah
- Emergency Duration: ≥ 3 Hours
- Lighting Source/Power: LED/20pcs 5050LED
- Luminance: >1 FC at 2.2m high
- Qty/20GP: 7080pcs
PRESSURE REDUCING VALVES
The Fireguard FG06-199 series Pressure Regulating Valves (PRV) are BSI-certified fire brigade valves manufactured to BS5041 Part 1, designed to maintain a constant, safe firefighting pressure in fire-water mains regardless of system location or fluctuating supply pressures. Particularly suited to high-rise buildings and wet riser installations, they ensure firefighting equipment always operates within safe working limits — from ground floor to the highest occupied level.
Consistent Pressure, Every Time In high-rise applications, static pressure in a wet riser can exceed safe operating limits for portable firefighting equipment. The FG06-199 PRV automatically regulates outlet pressure to a consistent 4.5–7 bar regardless of inlet pressure variations between 5.7 and 21 bar. The factory default setting of 7 bar is fully field-adjustable to suit the specific requirements of any installation.
Robust Construction Bodies are cast from LG2 bronze for exceptional corrosion resistance and longevity. Grey cast iron handwheels and a hydrostatically tested seat (to 20 bar) and body (to 30 bar) ensure reliable, long-term performance in demanding wet riser environments. Available in flanged (FG06-199A-00/A1-00) and screwed inlet (FG06-199B-00) configurations in DN50 and DN65 sizes, all with a standard 2½" BS336 instantaneous female outlet.
Key Specifications
- Inlet Pressure Range: 5.7–21 bar
- Outlet Pressure: 4.5–7 bar (factory set at 7 bar, fully adjustable)
- Hydrostatic Test: 20 bar (seat) / 30 bar (body)
- Body: LG2 Bronze | Handwheel: Grey cast iron
- Outlet: 2½" Female instantaneous BS336
- Available Sizes: DN50 / DN65
Certifications: BSI Certified | BS5041 Part 1 Compliant
FDC SINGLE CLAPPER
Fireguard's FGFDC425A Straight Way Fire Department Connection is FM Approved. Manufactured from solid brass components to increase service life. The single clapper design features a brass clapper and brass seats within a cast brass body. The 21/2” inlets are pin lug design for ease of use and compatibility with local fire service districts. Swivel gaskets are included. Breakable caps or plugs should be installed to protect threads and prevent debris from being accidentally introduced into the waterway. Features:
- Approval: FM Approved
- Female NPT x Female NST
- Working pressure: 300Psi
- Nominal Size: 2.45" x 4" x 2.5"