Panel Components

0 out of 5

ALU - ADDRESSABLE LOOP UNIT One ALU can support one addressable loop circuit, which supports up to 252 points of addressable devices. It can initialize and operate all devices residing on the loop and it communicates all relevant devices and event information, such as alarms and troubles, to the Central Processing Unit (CPU). No limitation between device types.   NOU - NOTIFICATION OUTPUT UNIT One NOU can support two independent notification appliance circuits with synchronization. The circuit topology supports Class A or Class B wiring. The maximum current is 2A per NAC. Multiple notification code types available.   ROU - RELAY OUTPUT UNIT One ROU card can support five dry contact relays: Alarm Relay, Supervisory Relay, Trouble Relay, Other Signal Relay, and Programmable Relay. The Relay contacts are in the C Form Style. The address is set by the rotary switch on the board. Valid address is 1. It meets the UL864 10th Edition Listed standard.   XNU - EXTERNAL NETWORK UNIT The IQ600E provides both Class X and Class B wiring to communicate with panels and annunciators in Network to form a fire network system. It meets the UL864 10th Edition standards. It can support up to 109 panels or remote annunciators.

View

FG901CP-MINI_AP Fire Control Panel

0 out of 5

FG901CP-MINI_AP is a microprocessor fire detection panel that allows the detection of fires through wired or wireless devices and can be programmed and interrogated through a fully touch screen interface.


Features
  • Able to manage an open or closed loop of 240 compatible devices, both optical and thermal.
  • The areas and zones controlled by detection devices can be combined by means of logical expressions in order to trigger events on the central unit and remote repeater panels.
  • Certified UNI EN 54-2 and 54-4 for fire detection and signalling systems, this control unit offers three different levels of access for different types of operators (installer, safety manager and end user).
  • The touch interface, simple and ergonomic, allows any type of user an intuitive interaction without time or training costs.
  • All configuration steps are immediate and the self-programming and self-addressing mechanisms allow you to recognize, interrogate and program devices in the field quickly, systematically and without errors.
  • The control panel can be programmed both locally and remotely, using the dedicated FG Cloud online platform, data can be exported and imported via any USB stick.
  • Monitoring takes place thanks to the WINWATCH32 supervision system.
  • The diagnostics of sensors and devices is carried out directly by the control panel and only one operator is able to independently run all the test procedures and verify the operation of the system in all its components.
  • Periodic maintenance can thus be planned and performed in an optimal way.
  • Diagnostic data and historical data recorded by the control panel can be easily exported and analysed in CVS/ excel format.
  • The control panel can be customized for all installation conditions: the mechanic colour, the display background, the colour of the programmable LEDs, the logo displayed on the welcome screen and the language can be chosen as desired.

View
,

Photo Electric Smoke Detector IQ651S

0 out of 5

The IQ651S is an intelligent Smoke Detector used with the IQ651B/IQ651BL Detector Base, is a UL listed device according to UL 268 for Fire Protective Signaling Systems for indoor use. It features a slim design that combines visual appeal with a high standard of reliability. It responds quickly and dependably to a broad range of fires. The detector has a Microcontroller Unit (MCU), performing comprehensive self-diagnostic tests and result analysis. The IQ651S is intelligent, addressable, and takes one address on the Signaling Line Circuit (SLC) of the fire alarm control panel.

View

Heat Detector IQ651H

0 out of 5

The IQ651H is an intelligent Heat Detector with both fixed-temperature alarm and rate-of-rise alarm characters (Temperature 135º F/57º C) is a UL listed device according to UL 521 for Fire Protective Signaling Systems for indoor use and FM. It features a slim design that combines visual appeal with a high standard of reliability. The detector has a Microcontroller Unit (MCU) performing comprehensive self-diagnostic tests, and result analysis. The IQ651H is intelligent, addressable, and takes one address on the signaling Line Circuit (SLC) of the fire alarm control panel.

View

Duct Detector IQ651DSC-A/B/C

0 out of 5

The IQ651DSC-A/B/C are ventilation duct detectors smart designed FOR USE WITH MODEL IQ651S DETECTOR HEADS. IQ651DSC are UL-listed devices according to UL 268A for fire protection systems. Equipped with a photoelectric smoke detector, the units will signal the presence of a dangerous amount of combustion product in the ventilation system. They are compatible with Fireguard’s control panel model IQ600 and IQ601. Note: These detectors are not designed to be used in open areas.

View

FG901CP-MININET_AP Fire Control Panel

0 out of 5

FG901CP-MININET_AP is a microprocessor fire detection panel that allows the detection of fires through wired or wireless devices and can be programmed and interrogated through a fully touch screen interface.


Features
  • The Multiprotocol panel, is able to manage an open or closed loop of 240 compatible devices, both optical and thermal. In complex applications it can be installed in a ring network.
  • In this distributed architecture, areas and zones controlled by detection devices can be combined by means of logical expressions in order to trigger events on the central unit of other panels of the ring network.
  • Certified UNI EN 54-2 and 54-4 for fire detection and signalling systems, this control unit offers three different levels of access for different types of operators (installer, safety manager and end user).
  • The touch interface, simple and ergonomic, allows any type of user an intuitive interaction without time or training costs.
  • All configuration steps are immediate and the self-programming and self-addressing mechanisms allow you to recognize, interrogate and program devices in the field quickly, systematically and without errors.
  • The control panel can be programmed both locally and remotely, using the dedicated OneCloud online platform, data can be exported and imported via any USB stick.
  • Monitoring takes place thanks to the WINWATCH32 supervision system.
  • The diagnostics of sensors and devices is carried out directly by the control panel and only one operator is able to independently run all the test procedures and verify the operation of the system in all its components.
  • Periodic maintenance can thus be planned and performed in an optimal way.
  • Diagnostic data and historical data recorded by the control panel can be easily exported and analysed in CVS/excel format.
  • The control panel can be customized for all installation conditions: the mechanic color, the display background, the color of the programmable LEDs, the logo displayed on the welcome screen and the language can be chosen as desired.

View
,

FG901CP-MINISL AP Fire Control Panel

0 out of 5

FG901CP-MINISL_AP is a microprocessor fire detection panel that allows the detection of fires through wired or wireless devices and can be programmed and interrogated through a fully touch screen interface.


Features
  • The Multiprotocol panel, is able to manage an open or closed loop of 126 compatible devices, both optical and thermal.
  • The areas and zones controlled by detection devices can be combined by means of logical expressions in order to trigger events on the central unit and remote repeater panels.
  • Certified UNI EN 54-2 and 54-4 for fire detection and signalling systems, this control unit offers three different levels of access for different types of operators (installer, safety manager and end user).
  • The touch interface, simple and ergonomic, allows any type of user an intuitive interaction without time or training costs.
  • All configuration steps are immediate and the self-programming and self-addressing mechanisms allow you to recognize, interrogate and program devices in the field quickly, systematically and without errors.
  • The control panel can be programmed both locally and remotely, using the dedicated FG Cloud online platform, data can be exported and imported via any USB stick.
  • The diagnostics of sensors and devices is carried out directly by the control panel and only one operator is able to independently run all the test procedures and verify the operation of the system in all its components.
  • Periodic maintenance can thus be planned and performed in an optimal way.
  • Diagnostic data and historical data recorded by the control panel can be easily exported and analysed in CVS/ excel format.
  • The control panel can be customized for all installation conditions: the mechanic colour, the display background, the colour of the programmable LEDs, the logo displayed on the welcome screen and the language can be chosen as desired.

View
,

Detector - FG901

0 out of 5

The new series of analogue sensors of the FG901 DETECTOR range constantly monitor the f ire alarm condition. The advanced design of the optical chamber ensures excellent resistance to dust entry, which means that the sensor’s performance is not compromised. Each sensor is equipped with drift compensation, it communicates its parameters to the control unit such as operating conditions, smoke darkening levels, dirt levels and temperature levels. Each sensor can be addressed manually, by programmer or by fire detection control unit with protocol or with auto addressing by fire detection control unit with protocol.


Models:
  • FG901SHD-AP
  • FG901SDI-AP
  • FG901HDI-AP

View

ADDRESSED SIREN WITH/WITHOUT FLASHING LIGHT

0 out of 5

The new family of addressed sirens of the FG901 SOUND line extends the range of devices addressed on loops with protocol. Simple to install, thanks to the extractable terminal board and the deep base, easy to program using dip switches and jumpers, they comply with EN54-3 and EN54-17 and in the case of FG901SF123_AP also with EN54-23. Each siren can be addressed manually, by programmer or by fire detection control unit with protocol or with auto addressing by fire detection control unit with protocol. All sirens are equipped with a short-circuit isolator conforming to the EN54-17 standard  


Features
  • Applus approved in compliance with EN54-3 EN54-17 standards (FG901S1_AP, FG901SF1_AP)
  • Applus approved in compliance with EN54-3 EN54-17 and EN54-23 standards (FG901SF123_AP)
  • Communication protocol
  • Isolator integrated in each device
  • Manual addressing via the programmer
  • Auto addressing for devices on loops even with “T” connections
  • Auto mapping function
  • Reading of the voltage value at the terminals of the addressed devices
  • FG901S1_AP Certificate n°1922-CPR-1141
  • FG901SF1_AP Certificate n°1922-CPR-1142
  • FG901SF123_AP Certificate n°1922-CPR-1143
Models:
  • FC901S1_AP
  • FG901SF1-AP
  •  FG901SF123_AP

View
,

AIR RELEASE VALVE

0 out of 5

Air release valve is used in wet pipe sprinkler systems and on casing of horizontal split case pump, so to automatically release small pockets of accumulated air while the system operates under pressure exceeding atmospheric pressure. Air Release Valves are designed to vent trapped air that collects at high points in a pipeline. These Valves continuously release air from piping systems thereby preventing large air pockets to form which can cause damaging pressure surge to the system. Air release valves permit trapped air to be released from piping systems without losing water pressure. The small orifice releases air under pressure during normal pipeline operation.

View

ALARM VALVE MODEL-H

0 out of 5

Alarm Valve is a double seated clapper check valve with grooved seat design, which ensures positive water flow for alarm operation and is designed for installation in wet pipe sprinkler system. External bypass prevents false alarm under all supply pressure condition. In the event of variable pressure condition, false alarm is prevented with the provision of retard chamber, thus the design allows for installation under both variable and constant supply pressure condition. Operation of one or more automatic fire sprinklers causes the water to flow into the sprinkler system causing the alarm valve to open, allowing continuous flow of water into the system and transmittal of alarm, both electrical and mechanical

View
,

ANGLE HOSE VALVE

0 out of 5

Angle pattern brass hose valves, with threaded connections, intended to control the flow of the water from the main risers in standpipe systems. Turning the handle counter clockwise the hose valve opens, allowing the water to flow out from the valve; turning the handle clockwise, the valve shuts off. Hose valves are used with a Fire Hose Rack Assembly, or as Fire Department outlet connections Model: FGAV105 -1.5” & 2.5”

View