EMERGENCY LIGHT MONITORING SYSTEM

0 out of 5

The emergency lighting testing and monitoring system is designed to test, maintain and manage independent powering emergency lights. Capable of automatic testing, data analysis and result judgment, this system improves the maintainability of emergency lights, thus increasing their reliability.  


Features
  • The Emergency Lighting Monitoring Control Panel has a 7-inch colorful touch screen, offering excellent man-machine interaction experience.  
  • Controlled by sound and light, the integrated controller automatically conducts real-time and efficient testing and inspection of operating states and faults of emergency lights. Events will be recorded and history can be retrieved.  
  • Logs can be displayed. History events can be viewed on the screen and imported into the computer.  
  • Timed automatic testing, which can test lights emergency functions according to the set time period.  
  • Timed battery maintenance, which can charge and discharge batteries according to the set time period so as to prolong the battery life.  
  • Emergency Lighting Monitoring Control Panel and interfaces are connected by CAN bus(The communication distance is up to 1Km). The interface and its subordinate devices are connected by RS485 bus (The communication distance is up to 1Km). The layout is simple and the cost is low.  
  • Maximum 64 interfaces within a Emergency Lighting Monitoring Control Panel, with each interface connecting up to 254 devices, Up to 16,320 devices can be managed simultaneously.

View
, ,

EMERGENCY LIGHTS FG-682L

0 out of 5

Specification

  •  Voltage: AC120V/227V 50/60Hz
  • AC power: 6W
  • Battery: Lead-Acid 6V 4.5Ah
  • Emergency Duration: ≥ 3 Hours
  • Lighting Source/Power: LED 2*3.2V/2W
  • Light Level: 10.8Lux
  • Qty/20GP: 6240pcs

View
,

EMERGENCY LIGHTS FG-601L

0 out of 5

Specification

  •  Voltage: AC120V/227V 50/60Hz
  • AC power: 7W
  • Battery: Ni-Cd 3.6V 4.5Ah
  • Emergency Duration: ≥ 3 Hours
  • Lighting Source/Power: LED/20pcs 5050LED
  • Luminance: >1 FC at 2.2m high
  • Qty/20GP: 7080pcs

View
, ,

EMERGENCY LIGHTS FG-680L

0 out of 5

Specification

  • Voltage: AC120V/227V 50/60Hz
  • AC power: 6W
  • Battery: Lead-Acid 6V 4.5Ah
  • Emergency Duration: ≥ 3 Hours
  • Lighting Source/Power: LED 2*3.2V/2W
  • Light Level: 10.8Lux
  • Qty/20GP: 3930pcs

View
, ,

EMERGENCY LIGHTS FG-604L

0 out of 5

Specification

  •  Voltage: AC120V/227V 50/60Hz
  • AC power: 7W
  • Battery: Ni-Cd 3.6V 4.5Ah
  • Emergency Duration: ≥ 3 Hours
  • Lighting Source/Power: LED/20pcs 5050LED
  • Luminance: >1 FC at 2.2m high
  • Qty/20GP: 5970pc

View
, ,

EMERGENCY LIGHTS FG-632L

0 out of 5

Specification

  • Voltage: AC120V/227V 50/60Hz
  • AC power: 7W
  • Battery: Ni-Cd 3.6V 4.5Ah
  • Emergency Duration: ≥ 3 Hours
  • Lighting Source/Power: LED/20pcs 5050LED
  • Luminance: >1 FC at 2.2m high
  • Qty/20GP: 7080pcs

View
,

PRESSURE REDUCING VALVES

0 out of 5

Fireguard Pressure Regulating Valves have been designed to maintain a uniform firefighting pressure in fire-water mains. Particularly suited for use in High Rise buildings the PRV will ensure that the pressure remains constant irrespective of the location. Pressure regulating valves are suitable for installation on wet risers in buildings for firefighting purposes. PRV can also be utilized in mains were normal pressures can be at an unacceptably high level and beyond the safe operating limits for the use of portable firefighting equipment. PRV will maintain constant, workable pressures when dealing with both high or low pressures making it an extremely versatile addition to any system. Pressure Regulating Valves are manufactured to BS5041 Part 1 ensuring durability and compatibility in harsh environments applications. PRV has a 2h" Instantaneous female outlet with inlet options with threaded or flanged models available. The static outlet pressure of the spring can be set between the following parameters as set out in the table below. The normal factory setting is at 7 bar but this is fully adjustable to suit individual requirements. Model:

  • Model: FG06-199A-00
  • Model: FG06-199A1-00
  • Model: FG06-199B-00

View
,

FDC SINGLE CLAPPER

0 out of 5

Fireguard Straight Way Fire Department Connection is FM Approved. Manufactured from solid brass components to increase service life. The single clapper design features a brass clapper and brass seats within a cast brass body. The 21/2” inlets are pin lug design for ease of use and compatibility with local fire service districts. Swivel gaskets are included. Breakable caps or plugs should be installed to protect threads and prevent debris from being accidentally introduced into the waterway.


Specification
  • Approval: FM Approved
  • Female NPT x Female NST
  • Working pressure: 300Psi
  • Nominal Size: 2.45" x 4" x 2.5"

View

FG901MCP_AP Manual Call Point

0 out of 5

The FG901MCP_AP is an intelligent analogue addressable manual call point designed to integrate seamlessly with fire detection control panels equipped with the ONEPROTOCOLL protocol. Built from robust red ABS with a front-mounted three-colour LED and key-resettable activation, it delivers reliable manual fire alarm initiation with the precision of addressable technology.

Integrated Isolator for Uninterrupted Communication Every FG901MCP_AP includes a built-in short-circuit isolator conforming to EN54-17, ensuring that a fault on the loop or a single device does not interrupt communication with the rest of the system — maintaining full network reliability at all times.

Flexible & Easy to Install Addressing is carried out via programmer or auto addressing through the control panel — no DIP or rotary switches needed. Auto addressing supports "T" connection topologies, and a removable terminal block accommodates cables up to 2.5mm² for straightforward wiring. An optional transparent protective cover is also available.

Key Specifications

  • Supply Voltage: 27V
  • Standby Current: 120 µA | LED Current: 6 mA
  • Loop Capacity: Up to 240 devices over 2km cable
  • Operating Temperature: -20°C to +65°C
  • Humidity: Up to 95% RH (non-condensing)
  • Ingress Protection: IP30
  • Dimensions: 87 × 87 × 54 mm | Weight: 110g

Certifications: Applus Certified (n°1922-CPR-1115) | EN54-11 & EN54-17 Compliant

View

FG901SB / FG901SBFR Sounder Base

0 out of 5

The FG901SB series are low-profile loop-powered sounder bases designed to mount directly beneath addressable detectors, combining notification and detection in a single discreet unit. Operating across a wide 16–40V DC input range, they deliver powerful, versatile audible alerting while protruding just 28mm from the ceiling — virtually unnoticeable until it matters most.

Two Models Available

The FG901SB_AP is the standard loop-powered sounder base, offering 32 primary and 32 alternative tones with 4 locally adjustable volume levels and sound output up to 92 dBA. Its acoustically optimised low-profile shape delivers omnidirectional coverage at ultra-low current draw.

The FG901SBFR_AP builds on this with an integrated VAD (Visual Alarm Device) beacon, adding a synchronised LED flash at 0.5Hz for visual notification alongside the audible alarm — ideal for environments requiring combined audible and visual alerting.

Key Features (both models)

  • Operating Voltage: 16–40V DC
  • Sound Output: Up to 92 dBA
  • Tones: 32 primary + 32 alternative
  • 4 locally selectable volume levels
  • Optical coverage level indicator
  • Ultra-low current consumption
  • Profile: 28mm wall/ceiling protrusion
  • Colour: White | Construction: Solid state electronics

FG901SBFR_AP additional feature: Synchronised LED flash at 0.5Hz

Certifications: CE Marked (1328)

View
,

FGMS ABORT AND RELEASE STATION

0 out of 5

FGMS Manual Pull Station is a high-quality non-toxic die-cast manual pull station. Low profile design and smooth edges offer an attractive yet functional design. All components are prepainted or have plated surfaces to inhibit corrosion. Electrically the FGMS Manual pull station is unbeatable with 10 Amp snap action switch offered in all possible contact arrangements (including gold contacts). The FGMS pull station can be used with or without a break glass rod with replacement requiring no special tools.

View
,

FIRE ALARM CABLE

0 out of 5

Characteristic

  • Conductor: Solid Bare Copper
  • Number of Conductor: 2
  • Size: 1.12mm
  • Insulation: PVC (RoHS Compliant)
  • Conductor Color Code: 1.Blue 2.Brown
  • Shielding: polyester foil + aluminium polyester foil shield
  • Drain Wire: a Stranded copper drain wire may be longitudinally laid to ensure electrical continuity of the screen.
  • Jacket: PVC (Flame-Retardant, RoHS Compliant)
  • Nominal Cable Diameter (in): 0.22
  • Minimum Bend Radius (in): 3.0
  • Maximum Pulling Force (lbs): 35
  • Temperature Rating (°F) Installation: +32 to + 140 Storage & Operation: -4 to + 167
Model:
  • 1.OMM22/C Solid Shield Fire Alarm Cable FPLR
  • 1.5MM22/C Solid Shield Fire Alarm Cable FPLR
  • 2.5MM22/C Solid Shield Fire Alarm Cable FPLR

View