EMERGENCY LIGHTS FG-682L
Specification
- Voltage: AC120V/227V 50/60Hz
- AC power: 6W
- Battery: Lead-Acid 6V 4.5Ah
- Emergency Duration: ≥ 3 Hours
- Lighting Source/Power: LED 2*3.2V/2W
- Light Level: 10.8Lux
- Qty/20GP: 6240pcs
EMERGENCY LIGHTS FG-601L
Specification
- Voltage: AC120V/227V 50/60Hz
- AC power: 7W
- Battery: Ni-Cd 3.6V 4.5Ah
- Emergency Duration: ≥ 3 Hours
- Lighting Source/Power: LED/20pcs 5050LED
- Luminance: >1 FC at 2.2m high
- Qty/20GP: 7080pcs
EMERGENCY LIGHTS FG-680L
Specification
- Voltage: AC120V/227V 50/60Hz
- AC power: 6W
- Battery: Lead-Acid 6V 4.5Ah
- Emergency Duration: ≥ 3 Hours
- Lighting Source/Power: LED 2*3.2V/2W
- Light Level: 10.8Lux
- Qty/20GP: 3930pcs
EMERGENCY LIGHTS FG-604L
Specification
- Voltage: AC120V/227V 50/60Hz
- AC power: 7W
- Battery: Ni-Cd 3.6V 4.5Ah
- Emergency Duration: ≥ 3 Hours
- Lighting Source/Power: LED/20pcs 5050LED
- Luminance: >1 FC at 2.2m high
- Qty/20GP: 5970pc
EMERGENCY LIGHTS FG-632L
Specification
- Voltage: AC120V/227V 50/60Hz
- AC power: 7W
- Battery: Ni-Cd 3.6V 4.5Ah
- Emergency Duration: ≥ 3 Hours
- Lighting Source/Power: LED/20pcs 5050LED
- Luminance: >1 FC at 2.2m high
- Qty/20GP: 7080pcs
PRESSURE REDUCING VALVES
Fireguard Pressure Regulating Valves have been designed to maintain a uniform firefighting pressure in fire-water mains. Particularly suited for use in High Rise buildings the PRV will ensure that the pressure remains constant irrespective of the location. Pressure regulating valves are suitable for installation on wet risers in buildings for firefighting purposes. PRV can also be utilized in mains were normal pressures can be at an unacceptably high level and beyond the safe operating limits for the use of portable firefighting equipment. PRV will maintain constant, workable pressures when dealing with both high or low pressures making it an extremely versatile addition to any system. Pressure Regulating Valves are manufactured to BS5041 Part 1 ensuring durability and compatibility in harsh environments applications. PRV has a 2h" Instantaneous female outlet with inlet options with threaded or flanged models available. The static outlet pressure of the spring can be set between the following parameters as set out in the table below. The normal factory setting is at 7 bar but this is fully adjustable to suit individual requirements. Model:
- Model: FG06-199A-00
- Model: FG06-199A1-00
- Model: FG06-199B-00
FDC SINGLE CLAPPER
Fireguard Straight Way Fire Department Connection is FM Approved. Manufactured from solid brass components to increase service life. The single clapper design features a brass clapper and brass seats within a cast brass body. The 21/2” inlets are pin lug design for ease of use and compatibility with local fire service districts. Swivel gaskets are included. Breakable caps or plugs should be installed to protect threads and prevent debris from being accidentally introduced into the waterway.
Specification
- Approval: FM Approved
- Female NPT x Female NST
- Working pressure: 300Psi
- Nominal Size: 2.45" x 4" x 2.5"
FG901MCP_AP Manual Call Point
The new analogue FG901MCP_AP communicates with all the fire-fighting control units equipped with the protocol, it can be reset using the supplied key and is equipped with a front LED and possibly with a transparent cover (optional). Each FG901MCP_AP can be addressed manually, by programmer or by fire detection control unit with FIREGUARD protocol or with auto addressing by fire detection control unit with protocol.
FG901SB_AP Sounder Base
FG901SB_AP Base Sounder operate over a wide input voltage range of 16 to 40V DC. The conventional range of detector base sounders are available in a standard 32 tone version in white with locally controllable output levels to enable the sound intensity to be adjusted to suit the application. This arrangement provides an extremely low-profile unit which is unobtrusive and protrudes only 28mm from the wall. The distinctive low-profile shape is acoustically very efficient, producing an omnidirectional high sound output at low current levels. Rugged construction with solid state electronics also provides high reliability and stable performance
Features
- Ultra low current
- 4 volume levels
- Optical coverage level
- 32 primary tones
- 32 alternative tones
- Up to 92 dba
FG901SBFR_AP Sounder Base
FG901SBFR_AP Base Sounder operate over a wide input voltage range of 16 to 40V DC. The conventional range of detector base sounders are available in a standard 32 tone version in white with locally controllable output levels to enable the sound intensity to be adjusted to suit the application and provide a synchronous LED flash rate 0.5Hz. This arrangement provides an extremely low-profile unit which is unobtrusive and protrudes only 28mm from the wall. The distinctive low-profile shape is acoustically very efficient, producing an omnidirectional high sound output at low current levels. Rugged construction with solid state electronics also provides high reliability and stable performance.
Features
- Ultra low current
- 4 volume levels
- Optical coverage level
- 32 primary tones
- 32 alternative tones
- Up to 92 dbA
- Synchronized flash
FGMS ABORT AND RELEASE STATION
FGMS Manual Pull Station is a high-quality non-toxic die-cast manual pull station. Low profile design and smooth edges offer an attractive yet functional design. All components are prepainted or have plated surfaces to inhibit corrosion. Electrically the FGMS Manual pull station is unbeatable with 10 Amp snap action switch offered in all possible contact arrangements (including gold contacts). The FGMS pull station can be used with or without a break glass rod with replacement requiring no special tools.
FIRE ALARM CABLE
Characteristic
- Conductor: Solid Bare Copper
- Number of Conductor: 2
- Size: 1.12mm
- Insulation: PVC (RoHS Compliant)
- Conductor Color Code: 1.Blue 2.Brown
- Shielding: polyester foil + aluminium polyester foil shield
- Drain Wire: a Stranded copper drain wire may be longitudinally laid to ensure electrical continuity of the screen.
- Jacket: PVC (Flame-Retardant, RoHS Compliant)
- Nominal Cable Diameter (in): 0.22
- Minimum Bend Radius (in): 3.0
- Maximum Pulling Force (lbs): 35
- Temperature Rating (°F) Installation: +32 to + 140 Storage & Operation: -4 to + 167
- 1.OMM22/C Solid Shield Fire Alarm Cable FPLR
- 1.5MM22/C Solid Shield Fire Alarm Cable FPLR
- 2.5MM22/C Solid Shield Fire Alarm Cable FPLR