Addressable Heat Fire Detector – IQ331H

0 out of 5

The IQ331H is a point-type heat fire detector, designed as a mated product for the IQ300 series fire alarm control panel. With an internal microprocessor, it supports electronic addressing over a two-wire bus, providing real-time temperature data to the panel and executing control commands received from it. The detector indicator blinks during routine polling and illuminates when the alarm threshold is reached, confirming a fire alarm at the panel.

Key Features:

  • Temperature compensation with sensor fault inspection
  • Non-polarity, two-wire bus for easy installation and maintenance
  • Remote indicator output included
  • Streamlined addressing via portable coder
  • 360° viewing with a single LED
  • Well suited to warehouses, loading bays, and underground carparks
  • Ideal for dirty or smoky environments; unaffected by wind or atmospheric pressure
  • LPCB certified

Key Specs:

  • Operating Voltage: Loop 24V (18–28V)
  • Standby Current: <0.3mA
  • Alarm Current: <1.5mA (without remote indicator) / <3.5mA (with remote indicator)
  • Class: A2
  • Fire LED: Red — flashes during polling, illuminates during alarm
  • Programming Range: One address within 1–324
  • Environmental Temperature: -10°C to +55°C
  • Relative Humidity: ≤95%, non-condensing
  • Material Enclosure: ABS
  • Dimensions: Ø100mm, 60mm height (with base)
  • Mounting Hole Distance: 44.5mm–64.3mm
  • Weight: ~155g (with base)

View

Addressable I/O Module – IQ361MO

0 out of 5

The IQ361MO addressable I/O module provides output control for fire linkage equipment such as smoke dampers, blow valves, and fire dampers, while also receiving feedback signals to confirm the equipment is operating normally. The module is designed to be installed on a DZ-9058 base.

Key Features:

  • LPCB approved
  • Semi-flush or surface mount
  • Reusable lever (non-glass break)
  • LED indicator
  • Full soft addressing, rewritable on-site via CODER-9001 encoder

Key Specs:

  • Operating Voltage: Single Loop 24V (20–28V) | Power 24VDC (20–28VDC)
  • Standby Current: Loop <0.8mA | Action Current: Loop <5mA, Power <15mA
  • Output Capacity: 1A @DC30V
  • Input Mode: NC or NO, set via jumper JP4
  • Programming: Electronically addressed | Code Range: One address within 1–324
  • Operating Temperature: -10°C to +55°C
  • Relative Humidity: ≤95%, non-condensing
  • Material of Enclosure: ABS
  • Dimensions: 86 x 86 x 41mm (with base)
  • Mounting Hole Distance: 60.5mm
  • Weight: ~132g (with base)

View

Addressable Loop Powered I/O Module – IQ361ML

0 out of 5

The IQ361ML addressable I/O module is designed for use with a loop-type fire alarm control panel. Powered via a non-polar two-wire bus, it requires no external 24V supply, offering low power consumption. The module connects conventional detectors, manual call points, or fire hydrant buttons, delivering the alarm signal directly to the controller. The IQ361ML is designed to be installed on a DZ-9057 base.

Key Features:

  • LPCB & CPR approved
  • Built-in standalone CPU for fast processing
  • Non-polarity two-wire bus — easy wiring, no external 24V supply needed
  • Connects conventional detectors, manual call points, or fire hydrant buttons

Key Specs:

  • Operating Voltage: Single Loop 24V (20–28V)
  • Standby Current: Loop <1.2mA | Action Current: Loop <4mA
  • Output Capacity: 2A @DC30V
  • Input Mode Setting: Set by coder F900E
  • Programming: Electronically addressed | Code Range: One address within 1–324
  • Operating Temperature: -10°C to +55°C
  • Relative Humidity: ≤95%, non-condensing
  • Material of Enclosure: ABS
  • Dimensions: 86 x 86 x 41mm (with base)
  • Mounting Hole Distance: 60.5mm
  • Weight: ~132g (with base)

View

Addressable Manual Call Point – IQ341CP

0 out of 5

The IQ341CP is a manual call point designed for use with an intelligent two-bus fire control system. When pressed to manually confirm a fire, it sends an alarm signal to the fire alarm control system, which displays the coded address and status of the call point. The red indicator blinks during normal operation and remains lit during an alarm. The IQ341CP supports electronic coding for convenient engineering applications.

Key Features:

  • LED for operational confirmation
  • Semi-flush or surface mounted, with optional waterproof protection cover
  • Resettable operating element with ergonomic reset key
  • Streamlined addressing via portable coder
  • Stable communication with high noise immunity
  • Non-polarity, two-wire bus connection for easy installation and maintenance
  • Passive output contacts for direct control of external equipment via intermediate relay
  • LPCB certified

Key Specs:

  • Operating Voltage: Loop 24V (18–28V)
  • Standby Current: <0.3mA | Alarm Current: <2mA
  • Initiating Mode: Manual pressing of frangible element | Resuming Mode: Manually resumed by special key
  • Address Range: One address within 1–324
  • Class: Type A, indoors
  • Ingress Protection: IP43
  • Environmental Temperature: -10°C to +55°C
  • Relative Humidity: ≤95%, non-condensing
  • Material of Enclosure: ABS
  • Dimensions: 90 x 90 x 42mm (overall) / 90 x 90 x 23mm (exposed after installation)
  • Weight: ~95g

View
,

Addressable module with integrated isolator in micro format FG901MMI_AP/ FG901MMO_AP /FG901MMIOS_AP

0 out of 5

The FG901MM series are ultra-compact addressable input/output micro-modules designed to interface a wide range of auxiliary devices — including sirens, entrance panels, and electromagnets — directly onto a fire detection loop. Despite their miniature footprint, each module incorporates a built-in short-circuit isolator, ensuring loop communication remains uninterrupted even in the event of a device or wiring fault.

Three Models for Every Application

  • FG901MMI_AP — Addressed input micro-module (1 supervised input, 1 address)
  • FG901MMO_AP — Addressed output micro-module (1 output, 1 address)
  • FG901MMIOS_AP — Combined input and output micro-module (1 input + 1 output, 2 addresses)

Effortless Installation At just 42×27×15mm and 30g, these modules fit virtually anywhere. Addressing is done via programmer or auto addressing through the control panel — no DIP or rotary switches needed. Auto addressing supports "T" connection topologies, and an auto mapping function speeds up commissioning further.

Key Specifications

  • Supply Voltage: 27V
  • Standby Current: 130 µA | LED Current: 6 mA
  • Operating Temperature: -5°C to +40°C
  • Humidity: Up to 95% RH (non-condensing)
  • Loop Capacity: Up to 240 addresses over 2km cable
  • Dimensions: 42 × 27 × 15 mm | Weight: 30g
  • Three-colour LED (red/green/yellow) panel-controlled
  • Construction: Matt white ABS, cable up to 2.5mm²

Certifications: Applus Certified (n°1922-CPR-1116) | EN54-17 & EN54-18 Compliant

View

Addressable Photoelectric Smoke Detector – IQ331S

0 out of 5

The IQ331S is a point-type photoelectric smoke detector with an internal microprocessor, supporting electronic addressing via a two-wire bus connected to a compatible fire alarm control panel. It provides real-time smoke concentration data to the panel and can receive and execute control commands from it.

Key Features:

  • Compensates for temperature, humidity, and dust drift; checks for sensor faults
  • Non-polarity, two-wire bus for easy installation and maintenance
  • Remote indicator output and patented smoke chamber to reduce false alarms
  • Simple addressing via portable coder
  • Single LED with 360° viewing
  • Suited to environments with rapid temperature changes, dirt, or smoke
  • LPCB certified

Key Specs:

  • Operating Voltage: Loop 24V (18–28V)
  • Standby Current: <0.3mA
  • Alarm Current: <1.5mA (without remote indicator) / <3.5mA (with remote indicator)
  • Fire LED: Red — flashes during polling, illuminates during alarm
  • Programming Range: One address within 1–324
  • Environmental Temperature: -10°C to +55°C
  • Relative Humidity: ≤95%, non-condensing
  • Dimensions: Ø100mm, 58mm height (with base)
  • Mounting Hole Distance: 44.5mm–64.3mm
  • Weight: ~128g (with base)

View

Addressable Sounder Beacon – IQ351S

0 out of 5

The IQ351S Intelligent Sounder Beacon provides an audible alarm signal when connected to a bus-type fire alarm control panel loop. On receiving a start command following a detected fire, the beacon emits a harsh audible signal to alert people on-scene, prompting evacuation and helping prevent a fire incident from escalating.

Key Features:

  • Meets both EN54-3 and EN54-23
  • Upper and lower cover design on an independent base for easy install, debug, and maintenance
  • Suitable for wall and ceiling mount applications
  • 16 selectable tones, set via 4-way DIP switch
  • Highly efficient LED technology with specially designed lens
  • Light output synchronization (EN54-23 compliant)
  • 3 operating modes: Sounder Only, Flasher Only, or Sounder/Flasher
  • Optional tamper-proof fixing
  • LPCB certified

Key Specs:

  • Operating Voltage: DC24V (18–28V)
  • Operating Current: ≤100mA @DC24V
  • Sound Output: ≥75dB(A) @1m (Tone 1)
  • Number of Tones: 16
  • EN54-23 Coverage: C-3-8 (ceiling) / W-2.4-6 (wall)
  • Flash Rate: 0.5Hz | Flash Color: White
  • Protection Class: IP21C
  • Operating Temperature: -10°C to +55°C, ≤95% RH non-condensing
  • Material: Flame retardant PC/ABS
  • Dimensions: Ø100mm x 100.5mm (with base)
  • Weight: ~266g

Coverage Volume (EN54-23 Approved):

Mount Type Dimensions Volume
Ceiling (C-3-8) X: 8m, Z: 3m 150.8 m³
Wall (W-2.4-6) X: 6m, Y: 6m, Z: 2.4m 86.4 m³

View

Addressable Sounder Beacon Base – IQ331SB

0 out of 5

The IQ331SB Addressable Sounder Beacon Base is a low power consumption, loop-powered base designed to reduce installation cost by combining a detector base with an integrated sounder beacon. IQ331S (smoke) or IQ331H (heat) detectors mount directly onto the base, enabling single-point connection. On receiving a start command from the fire alarm control panel, the base gives a dazzling visual signal and harsh audible alarm to alert people on-scene and prompt evacuation.

Key Features:

  • Meets EN54-3 standards
  • Easy, reliable rotating installation
  • Multiple super bright red LEDs for a highly visible display
  • Integrated detector base and sounder beacon — saves installation time, cost, and simplifies maintenance
  • Single-point connection for IQ331S and IQ331H detectors
  • LPCB certified

Key Specs:

  • Loop Unit: DC24V (20–28V), ≤2mA monitoring / ≤8mA alarm
  • Power Consumption: ≤0.2W @DC24V
  • Sound Output: ≥73dB(A) @1m
  • Flash Rate: 1–2Hz | Flash Color: Red
  • Protection Class: IP21C
  • Operating Temperature: -10°C to +55°C
  • Relative Humidity: ≤95%, non-condensing
  • Material Body: Flame retardant PC/PC+ABS
  • Dimensions: Ø115mm x H44mm (with bracket)
  • Weight: ~169g

Wiring: Terminals 1 & 3 connect to the fire alarm control panel loop (L1/L2); terminals 2 & 4 connect to the mounted IQ331S/IQ331H detector. Mode is configurable via CODER-F900E for Sounder & Beacon or Sounder-only operation.

View

Addressable Zone Module – IQ361MZ

0 out of 5

The IQ361MZ addressable zone module allows conventional photoelectric smoke detectors, conventional heat detectors, or other conventional devices to be connected to an addressable fire alarm control panel. When a connected conventional device gives an alarm, the module sends an alarm signal to the panel through the signal loop, supporting up to 30 conventional devices per module.

Key Features:

  • LPCB approved
  • LED indicator
  • Semi-flush or surface mount
  • Built-in standalone CPU for fast processing
  • Connects conventional detectors, manual call points, or fire hydrant buttons, delivering the alarm signal to the controller

Key Specs:

  • Operating Voltage: Single Loop 24V (20–28V) | Power 24VDC (20–28VDC)
  • Standby Current: Loop <0.5mA | Action Current: Loop <2mA, Power <35mA
  • Capacity: ≤30 conventional devices
  • Programming: Electronically addressed | Code Range: One address within 1–324
  • Operating Temperature: -10°C to +55°C
  • Relative Humidity: ≤95%, non-condensing
  • Material of Enclosure: ABS
  • Dimensions: 86 x 86 x 41mm (with base)
  • Mounting Hole Distance: 60.5mm
  • Weight: ~119g (with base)
  • Type of Base: DZ-9052

View

ATMOSPHERIC FOAM CONCENTRATE STORAGE TANK

0 out of 5

Horizontal atmospheric foam concentrate storage tanks designed for use with inline foam inductors and inline balance pressure foam proportioning systems. Available in capacities from 200 to 10,000 litres, these tanks are engineered for reliable, long-term storage of foam concentrates including AFFF and AR-AFFF types in fixed fire suppression installations.

Constructed from Stainless Steel (304 or 316) or Carbon Steel with FRP internal lining, each tank includes a 2% expansion dome to accommodate concentrate expansion, a sediment sump, sight gauge, air vent, and flanged suction and return connections as standard.

Key Specs:

  • Storage Capacity: 200 to 10,000 litres
  • Material: Stainless Steel (SS304 or SS316) or Carbon Steel with FRP lining
  • Expansion Dome: 2% of total tank capacity
  • Finish: Red RAL 3001 or Yellow
  • Connections: Flanged suction, return, fill, and drain

Standard Supply includes: Fill connection with expansion dome, drain connection, flanged suction and return connections, sight gauge, air vent, and lifting lugs.

Optional Accessories: Ladder, level switch/transmitter, custom nozzle connections, top platform, dished ends, vertical configuration, and seismic/structural analysis.

Compatible with AFFF and AR-AFFF foam concentrates. Must be installed in accordance with NFPA 11 or EN 13565-2. Contact us to specify tank capacity, material, and accessories.

View
,

BUTTERFLY VALVE GROOVED END & WAFER TYPE 300PSI

0 out of 5

UL Listed and FM Approved indicating-type butterfly valve designed for fire protection systems where visual confirmation of open or closed status is required. Commonly used as a system, sectional, or pump water control valve, available in both grooved end and wafer type configurations to suit a wide range of pipework arrangements.

The Model BO-G grooved end version can be fitted with a gear operator featuring two factory-installed internal SPDT switches, providing supervisory and auxiliary signalling to fire alarm control panels in accordance with NFPA 72. Valves can be installed with flow in either direction, in horizontal or vertical orientation.

Key Specs:

  • Sizes: 2½" to 12" (DN65 to DN300)
  • Max Working Pressure: 300 PSI (20.7 bar)
  • Body & Disc: Ductile Iron (ASTM A536) / Polyamide
  • Disc Seat: Grade EPDM "E" encapsulated rubber (ASTM D-2000)
  • Stem (Upper & Lower): Type 416 Stainless Steel (ASTM A582)
  • Approval: UL Listed (2½" to 8") | FM Approved (2½" to 8") | UL Listed only from 10" upward

Key Features: Visual open/closed indication, supervisory and auxiliary switch options, grooved end or wafer style configuration, suitable for any pipe schedule listed for fire protection use.

Must be installed and maintained in accordance with NFPA standards. Permission must be obtained from relevant authorities before closing any control valve for maintenance.

View

Controlled Dividing Breeching – Model FG-DB-2-33

0 out of 5

Fireguard's 2.5" light alloy instantaneous screw valve controlled dividing breeching takes a single water supply and divides it into two, allowing two hose lines to be fitted to one water supply for enhanced water delivery. Flow to each outlet is controlled via a screw-down valve.

Key Features:

  • Manufactured in light alloy
  • Suitable for 2.5" (64mm) lay flat hose
  • Inlet: 2½" Instantaneous Male to BS336
  • Outlet: 2 x 2½" Instantaneous Female to BS336
  • Complete with 2" screw down valve controls

View